With the increasing demand for sustainable energy, advanced characterization methods are becoming more and more important in the field of energy materials research. With the help of X-ray imaging technology, we can obtain the morphology, structure and stress change information of energy materials in real time from two-dimensional and three-dimensional perspectives. In addition, with the help of high penetration X-ray and high brightness synchrotron radiation source, in-situ experiments are designed to obtain the qualitative and quantitative change information of samples during the charge and discharge process. In this paper, X-ray imaging technology based on synchrotron and its related applications are reviewed. The applications of several main X-ray imaging technologies in the field of energy materials, including X-ray projection imaging, transmission X-ray microscopy, scanning transmission X-ray microscopy, X-ray fluorescence microscopy and coherent diffraction imaging, are discussed. The application prospects and development directions of X-ray imaging in the future are prospected.
In the present research work, we investigated the use of the image intensifier in the extraction of radiopaque foreign bodies in traumatology. First of all, it is necessary to clarify that this method constitutes an essential component of practically generalized use, in which low current level radiation is used, that is, fluoroscopic radiation, so that it can be applied for a considerably longer time than that of the longest radiographic exposure. This tool works with a tube intended for this purpose, which is known as fluoroscopy. The radiations from the tube pass through the patient and reach the serigraph, on which the image intensifier or fluoroscopic screen is mounted. In the latter case, this is where the chain ends, since it is on this screen that the image is formed and where the physician directly observes the region to be studied. It is also necessary to define that a foreign body is any element foreign to the body that enters it, either through the skin or through any natural orifice such as the eyes, nose, throat, preventing its normal functioning. It was possible to obtain as a result that the advantages of fluoroscopic navigation are the reduction of surgical time and the amount of irradiation, which goes from about 140 seconds without navigation to only 8 seconds, which is a substantial difference. Among the conclusions, it was possible to highlight that in the case of a radiopaque object, it is essential to have an image intensifier for localization of the foreign body during surgery; while in the case of a radiolucent foreign body, it is more advisable to locate it through the clinic, since these tend to form granulomas.
Industrial plastics have seen considerable progress recently, particularly in manufacturing non-lethal projectile holders for shock absorption. In this work, a variety of percentages of alumina (Al2O3) and carbon black (CB) were incorporated into high-density polyethylene (HDPE) to investigate the additive material effect on the consistency of HDPE projectile holders. The final product with the desired properties was controlled via physical, thermal, and mechanical analysis. Our research focuses on nanocomposites with a semicrystalline HDPE matrix strengthened among various nanocomposites. In the presence of compatibility, mixtures of variable compositions from 0 to 3% by weight were prepared. The reinforcement used was verified by X-ray diffraction (XRD) characterization, and thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) were used for thermal property investigation. Alumina particles increased the composites’ thermal system and glass transition temperature. Mechanical experiments indicate that incorporating alumina into the matrix diminishes impact resistance while augmenting static rupture stress. Scanning electron microscopy (SEM) revealed a consistent load distribution. Ultimately, we will conduct a statistical analysis to compare the experimental outcomes and translate them into mathematical answers that elucidate the impact of filler materials on the HDPE matrix.
The objective of the present study is to observe the surface morphology, structure and elemental composition of the ash particles produced from some thermal power stations of India using scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDXA). This information is useful to better understand the ash particles before deciding its utility in varied areas.
Introduction, purpose of the study: In Central Europe, in Hungary, the state guarantees access to health care and basic health services partly through the Semmelweis Plan adopted in 2011. The Health Plan aims to optimize and transform the health system. The objectives of hospital integration, as set out in the Plan, started with the state ownership of municipal hospitals in 2012, continued with the launch of integration processes in 2012–2013 and culminated today. The transformation of a health system can have an impact on health services and thus on meeting the needs of the population. We aim to study the effectiveness of integration through access to CT diagnostic testing. Our hypothesis is that integration has resulted in increased access to modern diagnostic services. The specialty under study is computed tomography (CT) diagnostic care. Our research shows that the number of people receiving CT diagnostic care has increased significantly because of integration, which has also brought a number of positive benefits, such as reduced health inequalities, reduced travel time, costs and waiting lists. Test material and method: Our quantitative retrospective research was carried out in the hospital of Kalocsa through document analysis. The research material was comparing two time periods in the Kalocsa site of Bács-Kiskun County, Southern Hungary. The number of patients attending CT examinations by area of duty of care according to postal codes was collected: Pre-integration period 2014.01.01–2017.11.30. (Kalocsa did not have CT equipment, so patients who appeared in Kecskemét Hospital but were under the care of Kalocsa), post-integration period 2017.12.01–2019.12.31. (period after the installation of CT in Kalocsa). The target group of the study consisted of women and men together, aged 0–99 years, who appeared for a CT diagnostic examination. The study sample size was 6721 persons. Linear regression statistics were used to evaluate the results. Based on empirical experience, a SWOT analysis was carried out to further investigate the effectiveness of integration. Results: As a result of the integration, the CT scan machine purchased in the Kalocsa District Hospital has enabled an average of 129.7 patients per month to receive CT scans on site without travelling. The model used is significant, explaining 86% of the change in the number of patients served (F = 43.535; p < 0.001, adjusted R2 = 0.860). The variable of integration in the model is significant, with an average increase in the number of patients served of 129.7 per month (t = 22.686; p < 0.001) following the introduction of CT due to integration. None of the month variables representing seasonal effects were found to be significant, with no seasonal effect on care. The SWOT analysis has clearly identified the strengths, weaknesses, opportunities and threats related to the integration, the main outcome of which is the acquisition of a CT diagnostic tool. Conclusions: Although we only looked at one segment of the evidence for the effectiveness of hospital integration, integration in the study area has had a positive impact on CT availability, reducing disparities in care.
In Costa Rica, there is no explicit recommendation from the competent authorities for the use of a specific phantom, so experts must explore what suppliers offer, among which the Normi Mam Digital phantom from PTW stands out. This article presents the results of the dosimetry and image quality control applied to the Normi Mam Digital phantom to validate it as equipment that complies with the recommendations of the Human Health Series No. 17. The results obtained were satisfactory, proving that the equipment complies with the tolerances recommended by international health bodies.
Copyright © by EnPress Publisher. All rights reserved.