The efficiencies and performance of gas turbine cycles are highly dependent on parameters such as the turbine inlet temperature (TIT), compressor inlet temperature (T1), and pressure ratio (Rc). This study analyzed the effects of these parameters on the energy efficiency, exergy efficiency, and specific fuel consumption (SFC) of a simple gas turbine cycle. The analysis found that increasing the TIT leads to higher efficiencies and lower SFC, while increasing the To or Rc results in lower efficiencies and higher SFC. For a TIT of 1400 ℃, T1 of 20 ℃, and Rc of 8, the energy and exergy efficiencies were 32.75% and 30.9%, respectively, with an SFC of 187.9 g/kWh. However, for a TIT of 900 ℃, T1 of 30 ℃, and Rc of 30, the energy and exergy efficiencies dropped to 13.18% and 12.44%, respectively, while the SFC increased to 570.3 g/kWh. The results show that there are optimal combinations of TIT, To, and Rc that maximize performance for a given application. Designers must consider trade-offs between efficiency, emissions, cost, and other factors to optimize gas turbine cycles. Overall, this study provides data and insights to improve the design and operation of simple gas turbine cycles.
The present work conducts a comprehensive thermodynamic analysis of a 150 MWe Integrated Gasification Combined Cycle (IGCC) using Indian coal as the fuel source. The plant layout is modelled and simulated using the “Cycle-Tempo” software. In this study, an innovative approach is employed where the gasifier's bed material is heated by circulating hot water through pipes submerged within the bed. The analysis reveals that increasing the external heat supplied to the gasifier enhances the hydrogen (H2) content in the syngas, improving both its heating value and cold gas efficiency. Additionally, this increase in external heat favourably impacts the Steam-Methane reforming reaction, boosting the H2/CH4 ratio. The thermodynamic results show that the plant achieves an energy efficiency of 44.17% and an exergy efficiency of 40.43%. The study also identifies the condenser as the primary source of energy loss, while the combustor experiences the greatest exergy loss.
In order to improve the quality and efficiency of heat treatment in welds of power stations, this paper summarizes the current situation of 600 MW supercritical power plant welding site heat treatment and puts forward the improved methods and measures accordingly. The heat treatment of welding holes in the construction site Play a certain guiding role.
In engineering, a design is best described based on its alternative performance operation. In this paper, an electric power plant is analysed based on its effective operational performance even during critical situation or crisis. Data is generated and analysed using both quantitative and qualitative research approach. During maintenance operation of an electric power plant, some components are susceptible to wide range of issues or crises. These includes natural disasters, supply chain disruptions, cyberattacks, and economic downturns. These crises significantly impact power plant operations and its maintenance strategies. Also, the reliable operation of power plants is often challenged by various technical, operational, and environmental issues. In this research, an investigation is conducted on the problems associated with electric power plants by proposing a comprehensive and novel framework to maintenance the power plant during crises. Based on the achieved results discussed, the framework impact and contribution are the integration of proactive maintenance planning, resilient maintenance strategies, advanced technologies, and adaptive measures to ensure the reliability and resilience of electric power plant during power generation operations in the face of unforeseen challenges/crisis. Hypothetical inferences are used ranging from mechanical failures to environmental constraints. The research also presents a structured approach to ensure continuous operation and effective maintenance in the electric power plant, particularly during crisis (such as environmental issues and COVID-19 pandemic issues).
In this study, daily averages of air quality parameters were measured in two stations (S1 and S2) of the organized industrial district in Samsun. The meteorological variables were measured at only one station (S1), such as temperature, relative humidity, wind speed, solar radiation, and ambient pressure in 2007, and the daily promised limit for nitrogen dioxide has been especially exceeded at 206 times for 1st station. However, exceeds of the limit value in 2006 for 1st station was reduced by approximately 3.5 times. The daily nitrogen dioxide concentration did not exceed the daily limit of WHO[1] as for 2nd station. The results obtained showed that under the influence of dominant wind direction, the second station measurement results are higher than that of the first station. To determine all of the possible environmental effects, the measurements should be analyzed from a multi-point perspective.
Air pollution in Jakarta has become a severe concern in the last four months. IQAir, in August 2023, revealed that the level of air pollution had reached 161 points on the Air Pollution Standard Index (APSI). The negative impact on society has placed air pollution as a concern for environmental safety and survival in danger. This condition will encourage the development of a national policy agenda to integrate environmental welfare through various energy efficiency channels. This research analyzes the relationship between air pollutant elements that can reduce air quality. The analysis includes pollutant intensity measured by APSI per unit of pollutant as a measure of efficiency. The aim is to observe energy use, which causes an increase in pollutant levels. This research utilizes dynamic system modeling to produce relationships between parameters to produce factors that cause pollution. The parameters used are motorized vehicles, waste burning in landfills, industry, and power plants. The results of historical behavioral tests and statistical suitability tests show that the behavior is suitable for the short and long term. The simulation results show that the pollution level will worsen by the end of 2027, a hazardous condition for society. The optimistic scenario simulation model proposes immediate counter-measures to reduce pollution to 45.01, the ideal condition. To accelerate improvements in air quality, the Government can plan policies to reduce the use of coal by power plants and industry, as well as the use of electric motorized vehicles, resulting in an ideal reduction in pollution by 2024. In conclusion, pollution can be reduced effectively if the Government firmly implements policies to maintain that air quality remains stable below 50 points.
Copyright © by EnPress Publisher. All rights reserved.