Every production day in Nigeria, and in other oil producing countries, millions of barrels of produced water is generated. Being very toxic, remediation of the produced water before discharge into environment or re-use is very essential. An eco-friendly and cost effective approach is hereby reported for remediative pre-treatment of produced water (PW) obtained from Nigerian oilfield. In this approach, Telfairia occidentalis stem extract-silver nanoparticles (TOSE-AgNPs) were synthesized, characterized and applied as bio-based adsorbent for treating the PW in situ. The nanoparticles were of average size 42.8 nm ± 5.3 nm, spherical to round shaped and mainly composed of nitrogen and oxygen as major atoms on the surface. Owing to the effect of addition of TOSE-AgNPs, the initially high levels (mg/L) of Total Dissolved Solids (TDS), Biological Oxygen Demand (BOD) and TSS of 607, 3.78 and 48.4 in the PW were reduced to 381, 1.22 and 19.6, respectively, whereas DO and COD improved from 161 and 48.4 to 276 and 19.6 respectively, most of which fell within WHO and US-EPA safe limits. Particularly, the added TOSE-AgNPs efficiently removed Pb (II) ions from the PW at temperatures between 25 ℃ to 50 ℃. Removal of TOSE-AgNPs occurred through the adsorption mechanism and was dependent contact time, temperature and dose of TOSE-AgNPs added. Optimal remediation was achieved with 0.5 g/L TOSE-AgNPs at 30 ℃ after 5 h contact time. Adsorption of Pb (Ⅱ) ions on TOSE-AgNPs was spontaneous and physical in nature with remediation efficiency of over 82% of the Pb (Ⅱ) ions in solution. Instead of discarding the stem of Telfairia occidentalis, it can be extracted and prepared into a new material and applied in the oilfield as reported here for the first time.
This research focuses on patients’ perceptions regarding the accessibility of dental services in Slovenia across four dimensions: financial accessibility, time accessibility, geographical accessibility, and service quality. We observed how specific factors impact accessibility dimensions of dental services in Slovenia, that patients perceive important. A cross-sectional quantitative survey was conducted using proportionate stratified sampling. Data was collected through an online questionnaire, and 599 completed responses were received from patients regarding their experiences and perceptions of accessibility to dental care. A SEM (structural equation model) approach was used to examine the data. The analysis revealed that patients perceive all four dimensions of accessibility: financial, time, geographical, and service quality important and they all constitute the perception of dental accessibility. The findings of this study can assist policymakers in developing a more accessible dental health system by considering the results proposed in our model.
Simulation training in dental medical eduaction is a modern high-tech approach in providing quality higher education. Simulation training immerses students in realistic scenarios, allowing them to develop both technical and non-technical skills essential for effective patient care. This study highlights key contemporary issues in high-tech simulation training for dental education and consolidates its rationale and benefits. We searched the databases PubMed, Scopus, Web of Science, and ResearchGate. This review includes 36 articles published in English, Russian, and Ukrainian from 2020 to 2024. Non-peer-reviewed papers or those not published in indexed journals were not considered. Simulation training was found to impact integration of theory and practice, training a wide range of psychomotor skills, development of complex clinical competences, cultivating confidence, empathy and patient-oriented care, neuroplasticity of the brain and the cognitive load. Pedagogical benefits and the place of simulation training in the curriculum were also discussed.
Introduction: Periodontal disease affects more than half of the population in Colombia and is estimated to be one of the leading causes of oral morbidity. Diagnostic aids that allow the evaluation of its extension and severity are of importance since this will provide reliable tools to quantify the severity of the problem. Objective: To determine the inter-examiner agreement for the detection of radiographic findings in patients with localized chronic periodontitis using conventional periapical radiography. Methods: Study of diagnostic tests including patients with localized chronic periodontitis, the tooth with the worst clinical insertion level and a single conventional radiograph per dental organ using parallelism technique. The radiographic evaluations were performed by two independent and blinded evaluators for the findings: lamina dura, bone defects and type of defect. The agreement obtained was estimated through Cohen’s Kappa. Results: A total of 125 radiographs were taken. The mean age was 38.8 ± 9.9, and 61.6% were women. Concordance for lamina dura was 0.08 (95% CI: -0.04–0.21), bone defects 1.00 (95% CI: 1.00–1.00); type of defect present 0.31 (95% CI: 0.29–0.38). Conclusions: Concordance was evaluated as null, almost perfect and acceptable for the findings lamina dura, presence of bone defects and type of defect respectively. For some findings and given the importance of the diagnostic and therapeutic processes, more accurate evaluations are needed which would result in a higher degree of agreement.
Introduction: In Colombia, the last oral health study showed that about 70% of the population has partial edentulism while 5.2% will have lost all their teeth between the age of 65 and 79. Rehabilitation with implants is an increasingly used option, which requires clinical and radiographic follow-up. Panoramic radiography is a low-cost option, in which it is possible to observe areas of bone loss, mesiodistal angulation of the implant, relationship with anatomical structures and lesions suggestive of peri-implantitis. Reports and analysis of relevant data on radiographic findings associated with dental implants are required to determine the risk factors for their success in patients who use them. Objective: To determine the prevalence and characterize the findings associated with osseointegration implants in panoramic radiographs. Methods: A descriptive cross-sectional observational study was carried out with 10,000 digital panoramic radiographs selected by convenience from radiological centers in the city of Bogota, Colombia, of which 543 corresponded to the sample analyzed for the presence of implants. The following were evaluated for each implant: location, position, angulation and distances to adjacent structures, using the Clínicalview® program (Orthopantomograph OP200D, Instrumentarium, USA). Results: The frequency of radiographs with implants was 5.43% with a total of 1,791 implants, with an average of 3.2 per radiograph. They were found in greater proportion in the upper jaw with a supracrestal location and an angulation of 10.3 degrees. 32% had implant/tooth or implant/implant distances that were less than optimal. 40.9% were restored and 1.2% showed lesions compatible with periimplantitis. Conclusions: A high percentage of the implants reviewed have a risk factor that affects their long-term viability, either due to angulation, supracrestal or crestal position, proximity to teeth or other implants, or because they are not restorable.
Introduction: It is universally accepted that the posteroanterior skull radiograph shows a lower degree of distortion than other radiographic images, so that measurements on it are considered reliable. Objective: To determine the percentage of distortion in the different facial regions of the postero-anterior skull radiograph. Methods: Thirty human skulls with their jaws were divided by three horizontal and four vertical planes into fifteen quadrants; there were ten in the skull and five in the jaw. On each of them a steel wire was placed in vertical and horizontal positions and their length (actual measurement) was measured. Each set was X-rayed in posteroanterior projection and the length of the wires was measured in the image (radiographic measurement). Results: It was not possible to measure in the lateral quadrants of the skull. The horizontal measurement in the right and left lower intermediate quadrants of the skull and in the intermediate and lateral quadrants of both sides of the mandible is not reliable; in the median quadrant of the mandible it is minimized; in the right and left upper intermediate and median quadrants of the skull and in the median of the mandible it is magnified. Vertical measurements in all quadrants are reliable; in the right and left upper intermediate and left upper and middle quadrants of the skull and in the right and left middle and lateral quadrants of the mandible it is magnified; in the lower intermediate and upper and lower middle quadrants of the skull and median of the mandible it is minimized. The least distortion for both measurements occurs in the upper median quadrant of the skull. Percentages of distortion are reported for each quadrant. Conclusions: Distortion is present in the posteroanterior skull radiograph and varies from one region of the face to another.
Copyright © by EnPress Publisher. All rights reserved.