Clinical/methodological problem: The identification of clinically significant prostate carcinomas while avoiding overdiagnosis of low-malignant tumors is a challenge in routine clinical practice. Standard radiologic procedures: Multiparametric magnetic resonance imaging (MRI) of the prostate acquired and interpreted according to PI-RADS (Prostate Imaging Reporting and Data System Guidelines) is accepted as a clinical standard among urologists and radiologists. Methodological innovations: The PI-RADS guidelines have been newly updated to version 2.1 and, in addition to more precise technical requirements, include individual changes in lesion assessment. Performance: The PI-RADS guidelines have become crucial in the standardization of multiparametric MRI of the prostate and provide templates for structured reporting, facilitating communication with the referring physician. Evaluation: The guidelines, now updated to version 2.1, represent a refinement of the widely used version 2.0. Many aspects of reporting have been clarified, but some previously known limitations remain and require further improvement of the guidelines in future versions.
Amyloidosis is a systemic disorder produced by the deposition of insoluble protein fibrils that fold and deposit in the myocardium. Patients with amyloidosis and cardiac involvement have higher mortality than patients without cardiac involvement. The two most prevalent forms of amyloidosis associated with cardiac involvement are AL amyloidosis, due to the deposition of immunoglobulin light chains, and ATTR amyloidosis, due to the deposition of the transthyretin (TTR) protein in mutated or senile form. This article aims to review the different cardiac imaging modalities (echocardiography, cardiac magnetic resonance imaging, nuclear medicine and tomography) that allow to determine the severity of cardiac involvement in patients with amyloidosis, the type of amyloidosis and its prognosis. Finally, we suggest a diagnostic algorithm to determine cardiac involvement in amyloidosis adapted to locally available diagnostic tools, with a practical and clinical approach.
Introduction: Stenoses in the path of arteriovenous fistulas (AVF) for hemodialysis are a very prevalent problem and there is long experience in their treatment by percutaneous angioplasty (PTA). These procedures, however, involve non-negligible equipment requirements, exposure to radiation and intravenous contrast that are not beneficial for the patient and make their performance more complex. This study reviews our initial experience with Doppler ultrasound-guided angioplasty. Methods: Prospective cohort of patients with native AVF dysfunction due to significant venous stenosis treated by Doppler echo-guided PTA. AVF puncture, lesion catheterization, balloon localization and inflation, and outcome verification were performed under ultrasound guidance. Only one fistulography was performed before and another one after dilatation. As a control, the cases performed during the same period by the usual angiographic method were also collected. Results: Between February 2015 and September 2018, 51 PTAs were performed on native AVF, of which 27 were echogenic (mean age, 65.3 years; 63% male). The technical success rate was 96%. In 26% of cases, PTA was repeated due to residual stenosis after angiographic imaging. There were 7.3% periprocedural complications. 92% of the AVFs were punctured at 24 hours. Primary patency at 1 month, 6 months and 1 year was 100%, 64.8% and 43.6%, and assisted patency was 100%, 87.2% and 74.8%. There were no significant differences in immediate or late results with respect to angiographically guided AVF angioplasty. Conclusions: AVF-PTA can be performed safely and effectively guided by Doppler ultrasound, which simplifies the logistics required for its performance, although we still need to improve the capacity for early verification of the result with this imaging technique.
Imaging technology plays a key role in guiding endovascular treatment of aortic aneurysm, especially in the complex thoracoabdominal aorta. The combination of high quality images with a sterile and functional environment in the surgical suite can reduce contrast and radiation exposure for both patient and operator, in addition to better outcomes. This presentation aims to describe the current use of this technique, combining angiotomography and intraoperative cone beam computed tomography, image “fusion” and intravascular ultrasound, to guide procedures and thus improve the intraoperative success rate and reduce the need for reoperation. On the other hand, a procedure is described to create customized 3D templates with the high-definition images of the patient’s arterial anatomy, which serve as specific guides for making fenestrated stents in the operating room. These customized fenestration templates could expand the number of patients with complex aneurysms treated minimally invasively.
Objective: to determine the diagnostic performance of magnetic resonance hysterosalpingography (HSG-MRI), using laparoscopy as the reference method. Materials and methods: 22 patients were included. All underwent HSG-MRI with a 1.5 Tesla resonator and then laparoscopy with chromotubation. Two radiologists examined the MRIs, determining tubal patency by consensus. Descriptive and diagnostic performance analyses were performed. Results: HSG-MRI had a success rate of 91%. Study duration was 49 ± 15 minutes, volume injected 26 ± 16 cm3 and pain scale 30 ± 19 out of 100. Sensitivity and specificity of HSG-MRI were 100% for global and left Cotte test, and 25% and 93.3% for right Cotte test, respectively. There were 2 minor complications and no major complications. Discussion: our initial results demonstrated high sensitivity and specificity. Although other studies analyzed the ability of HSG-MRI to assess tubal patency with good results, the use of a flawed reference standard left room for reasonable doubt, preventing a recommendation based on solid evidence. However, when comparing our results with those published, we observed a high degree of concordance insofar as the positive effusion is correctly diagnosed with a specificity of 100% or with a percentage close to this figure.
The possibility of preoperative prediction of pathologic complete response in rectal cancer has been studied in order to identify patients who would respond to neoadjuvant therapy and to individualize therapeutic strategies. Endoscopic ultrasound of the rectum is an accurate method for the evaluation of local tumor and lymph node invasion. Objective: To evaluate the potential of endoscopic ultrasound as a predictor of complete pathological response to neoadjuvant treatment in patients with locally advanced rectal cancer. Material and methods: Retrospective study of patients with rectal cancer from January 2014 to December 2016. Results: We obtained a statistical association between T stage by endoscopic ultrasound and complete pathological response (p = 0.015). It is not so for N, sphincter involvement, circumferential involvement and maximum tumor thickness (p = 0.723, p = 0.510, p = 0.233 and p = 0.114, respectively). When multivariate logistic regression analysis was applied to assess the degree of influence of the predictor variables on pathologic response, none of these variables was associated with complete pathologic response. Conclusion: Prediction of pathologic complete response in rectal cancer has been considered as the crucial point upon which treatments for rectal cancer could be individualized. So far, no imaging method has been able to demonstrate efficacy in predicting complete pathologic response, and in turn there is no direct association between any endosonographic finding that can accurately predict it.
Copyright © by EnPress Publisher. All rights reserved.