Objective: To evaluate the clinical and radiographic results and complications of arthroscopic subcapital realignment osteotomy for the treatment of chronic and stable proximal femoral epiphysiolysis (PFE) in an initial series of patients. According to the literature review, the study presents the first description of an arthroscopic technique of this type of osteotomy. Methods: Between June 2012 and December 2014, seven patients underwent arthroscopic subcapital realignment osteotomy for the treatment of chronic, stable PFE. The mean age of the patients was 11 years and four months. Minimum follow-up ranged from 6 to 36 months (mean, 16.5 months). Patients were clinically evaluated according to the Harris Hip Score modified by Byrd and radiographically according to Southwick’s quantitative classification and the epiphyseal-diaphyseal angle. Postoperative complications were analyzed. Results: With regard to the evaluation of the Harris Hip Score Modified by Byrd clinical score, a preoperative mean of 35.8 points and a postoperative mean of 97.5 points were observed (p < 0.05). Radiographically, five patients were classified as Southwick grade II and two as grade III. A mean correction of the epiphyseal-diaphyseal angle of 40° was observed. There were no immediate postoperative complications. One patient developed avascular necrosis of the femoral head, without collapse or chondrolysis at the last follow-up (22 months). Conclusion: The arthroscopic technique presented by the authors for the treatment of chronic, stable PFE resulted in clinical and radiographic improvement of the patients in this initial series.
Amyloidosis is a systemic disorder produced by the deposition of insoluble protein fibrils that fold and deposit in the myocardium. Patients with amyloidosis and cardiac involvement have higher mortality than patients without cardiac involvement. The two most prevalent forms of amyloidosis associated with cardiac involvement are AL amyloidosis, due to the deposition of immunoglobulin light chains, and ATTR amyloidosis, due to the deposition of the transthyretin (TTR) protein in mutated or senile form. This article aims to review the different cardiac imaging modalities (echocardiography, cardiac magnetic resonance imaging, nuclear medicine and tomography) that allow to determine the severity of cardiac involvement in patients with amyloidosis, the type of amyloidosis and its prognosis. Finally, we suggest a diagnostic algorithm to determine cardiac involvement in amyloidosis adapted to locally available diagnostic tools, with a practical and clinical approach.
The micro staring hyperspectral imager can simultaneously acquire two spatial and one spectral images, and only record the external orientation elements of the entire hyperspectral image rather than the external orientation elements of each frame of the image, which avoids the geometric instability during scanning, effectively solves the problem of large geometric deformation of the small line scanning hyperspectral imager, and is suitable for the small UAV load platform with unstable attitude. At present, most of the research focuses on the radio-metric correction method of line scan hyperspectral imager. The application time of staring hyperspectral imager is short, and there is no mature data processing re-search at home and abroad, which hinders the application of UAV micro staring hyperspectral imaging system. In this paper, the calibration method of the linearity and variability of the radiation response of the micro staring hyperspectral imager on the UAV is studied, and the effectiveness of this method is quantitatively evaluated. The results show that the hyperspectral image has obvious vignetting effect and strip phenomenon before the correction of radiation response variability. After the correction, the radiation response variation coefficient of pixels in different bands decreases significantly, and the vignetting effect and image strip decrease significantly. In this paper, a multi-target radiometric calibration method is proposed, and the accuracy of radiometric calibration is verified by comparing the calibrated hyperspectral image spectrum with the measured ground object spectrum of the ground spectrometer. The results show that the calibration results of the multi-target radiometric calibration method show better results, especially for the near-infrared band, and the difference with the surface reflectance measured by the spectrometer is small.
Copyright © by EnPress Publisher. All rights reserved.