In the present study, friction damper, an energy dissipating passive device is explored to reduce the response of open ground storey building under lateral loading due to earthquake. This damper is installed in the selected bays of open ground storey so that the response is reduced. The masonry infill wall is macro-modeled in the form of compression only diagonal members. Three different types of bracing system were installed along with Pall friction damper – single diagonal tension – compression brace with friction damper, tension only cross brace with friction damper and chevron brace with friction damper were modeled using Wen’s plastic link element in SAP2000. G+4 storey buildings were analyzed using nonlinear time history analysis. The storey displacement and inter-storey drift for all the cases were compared in the study.
To investigate the possible role of arbuscular mycrrhizal fungi (AMF) in alleviating the negative effects of salinity on Stevia rebaudiana (Bert.), the regenerated plantlets in tissue culture was transferred to pots in greenhouse and inoculated with Glomus intraradices. Salinity caused a significant decrease in chlorophyll content, photosynthesis efficiency and enhanced the electrolyte leakage. The use of AMF in salt –affected plants resulted in improved all above mentioned characteristics. Hydrogen peroxide and malondialdehyde (MDA) contents increased in salt stressed plants while a reduction was observed due to AMF inoculation. CAT activity showed a significant increase up to 2 g/l and then followed by decline at 5 g/l NaCl in both AMF and non-AMF treated stevia, however, AMF inoculated plants maintained lower CAT activity at all salinity levels (2 and 5 g/l). Enhanced POX activities in salt- treated stevia plants were decreased by inoculation of plants with AMF. The addition of NaCl to stevia plants also resulted in an enhanced activity of SOD whilst, AMF plants maintained higher SOD activity at all salinity levels than those of non-AMF inoculated plants. AMF inoculation was capable of alleviating the damage caused by salinity on stevia plants by reducing oxidative stress and improving photosynthesis efficiency.
Investment growth in many emerging market and developing economies (EMDEs) has slowed sharply since 2010. Investment growth performance has varied significantly across different regions, however. This paper examines the evolution of investment growth in six EMDE regions, documents remaining investment needs, especially for infrastructure, and presents a set of region-specific policy responses to address these needs. It reports three main findings. First, investment growth has been particularly weak in EMDE regions hosting a large number of commodity exporters. In regions with a substantial number of commodity-importing economies, investment growth has been somewhat resilient but has also declined steadily since 2010. Second, sizable investment needs remain in most EMDE regions to make room for expanding economic activity and rapid urbanization. A large portion of these investment needs is in infrastructure and human capital. Finally, while specific policy priorities vary across regions, several policy options to address remaining investment needs apply universally. These include more, and more efficient, public investment and measures to improve overall growth prospects and the business climate. Improved project selection and monitoring, as well as better governance, may enhance the efficiency and benefits from public investment.
Currently there is a great acceptance in medicine and dentistry that clinical practice should be “evidence-based” as much as possible. That is why multiple works have been published aimed at decreasing radiation doses in the different types of imaging modalities used in dentistry, since the greater effect of radiation, especially in children, forces us to take necessary measures to rationalize its use, especially with Cone Beam computed tomography (CBCT), the method that provides the highest doses in dentistry. This review was written using such an approach with the purpose of rationalizing the radiation dose in our patients. In order to formulate recommendations that contribute to the optimization of the use of ionizing radiation in dentistry, the SEDENTEXCT project team compiled and analyzed relevant publications in the literature, guidelines that have demonstrated their efficiency in the past, thus helping to see with different perspectives the dose received by patients, and with this, it is recommended taking into account this document so as to prescribe more adequately the complementary examinations that we use on a daily basis.
The micro staring hyperspectral imager can simultaneously acquire two spatial and one spectral images, and only record the external orientation elements of the entire hyperspectral image rather than the external orientation elements of each frame of the image, which avoids the geometric instability during scanning, effectively solves the problem of large geometric deformation of the small line scanning hyperspectral imager, and is suitable for the small UAV load platform with unstable attitude. At present, most of the research focuses on the radio-metric correction method of line scan hyperspectral imager. The application time of staring hyperspectral imager is short, and there is no mature data processing re-search at home and abroad, which hinders the application of UAV micro staring hyperspectral imaging system. In this paper, the calibration method of the linearity and variability of the radiation response of the micro staring hyperspectral imager on the UAV is studied, and the effectiveness of this method is quantitatively evaluated. The results show that the hyperspectral image has obvious vignetting effect and strip phenomenon before the correction of radiation response variability. After the correction, the radiation response variation coefficient of pixels in different bands decreases significantly, and the vignetting effect and image strip decrease significantly. In this paper, a multi-target radiometric calibration method is proposed, and the accuracy of radiometric calibration is verified by comparing the calibrated hyperspectral image spectrum with the measured ground object spectrum of the ground spectrometer. The results show that the calibration results of the multi-target radiometric calibration method show better results, especially for the near-infrared band, and the difference with the surface reflectance measured by the spectrometer is small.
Copyright © by EnPress Publisher. All rights reserved.