Heat transfer enhancement (HTE) is a topic of everlasting importance in thermal engineering research. The latest focuses in this field are on nanosolutions for more efficient thermal transmission fluids (a) and designs of metallic foams (b) Metallic foams provide extended surfaces for HTE and possess advantages such as a high value of Cp, high thermal conductivity (TC) and being light weight. nanosolutions, on the other hand, can be used as an efficient HT medium as they exhibit higher TCs in comparison to base fluids. This review paper summarizes the physical properties of nanosolutions and or within the metal foam, focusing on HT and flow properties of nanosolutions, metal foam and combined NS-metal foam systems. The inspiration novelty for this review is the basic transference identifications for the HT enhancement of nanosolutions in porous media. The aim of the work is to provide insight on how nanosolutions in conjunction with porous media can be useful for HTE.
Medicare, a major healthcare program under the Centers for Medicare & Medicaid Services (CMS) has extended telemedicine services within several states in the US for different specialties for which it reimburses in order to establish a qualitative and accessible healthcare system. In parallel, it has been seen that teleradiology services by American Board Certified radiologists based offshore can significantly supplement healthcare delivery in the US by mitigating the shortage of radiologists and enhance outcomes of patient care especially for after-hours emergency work. Teleradiology can help workflow by improving workload distribution, lowering the cost of reporting, shortening turn-around-time for reports, and improving quality of life for staff. The aim of the article is to provide perspective on Medicare reimbursement of offshore telereporting services. We submit that due to its value proposition and contribution to healthcare, offshore telereporting by American Board Certified Radiologists is worthy of Medicare reimbursement and should be re-evaluated for its credits.
ZrO2 thin film samples were produced by the sol-gel dip coating method. Four different absorbed dose levels (such as ~ 0.4, 0.7, 1.2 and 2.7 Gray-Gy) were applied to ZrO2 thin films. Hence, the absorbed dose of ZrO2 thin film was examined as physical dose quantity representing the mean energy imparted to the thin film per unit mass by gamma radiation. Modification of the grain size was performed sensitively by the application of the absorbed dose to the ZrO2 thin film. Therefore the grain size reached from ~50 nm to 87 nm at the irradiated ZrO2 thin film. The relationship of the grain size, the contact angle, and the refractive index of the irradiated ZrO2 thin film was investigated as being an important technical concern. The irradiation process was performed in a hot cell by using a certified solid gamma ray source with 0.018021 Ci as an alternative technique to minimize the utilization of extra toxicological chemical solution. Antireflection and hydrophilic properties of the irradiated ZrO2 thin film were slightly improved by the modification of the grain size. The details on the optical and structural properties of the ZrO2 thin film were examined to obtain the optimum high refractive index, self-cleaning and anti-reflective properties.
The regulation of compressor extraction and energy storage can improve the performance of gas turbine energy system. In order to make the gas turbine system match the external load more flexibly and efficiently, a gas turbine cogeneration system with solar energy coupling compressor outlet extraction and energy storage is proposed. By establishing the variable condition mathematical model of air turbine, waste heat boiler and solar collector, we use Thermoflex software to establish the variable condition model of gas turbine compressor outlet extraction, and analyze the variable condition of the coupling system to study the changes of thermal parameters of the system in the energy storage, energy release and operation cycle. Taking the hourly load of a hotel in South China as an example, this paper analyzes the case of the cogeneration system of solar energy coupling compressor outlet extraction and energy storage, and compares it with the benchmark cogeneration system. The results show that taking a typical day as a cycle, the primary energy utilization rate of the system designed in this paper is 3.2% higher than that of the traditional cogeneration system, and the efficiency is 2.4% higher.
In this study, the development of rinnenkarren systems is analyzed. During the field studies, 36 rinnenkarren systems were investigated. The width and depth were measured at every 10 cm on the main channels and then shape was calculated to these places (the quotient of channel width and depth). Water flow was performed on artificial rinnenkarren system. A relation was looked for between the density of tributary channels and the average shape of the main channel, between the distance of tributary channels from each other and the shape of a given place of the main channel. The density and total length of the tributary channels on the lower and upper sections of the main channels being narrow at their lower end (11 pieces) and being wide at their lower end (10 pieces) of the rinnenkarren systems were calculated as well as their average proportional distance from the lower end of the main channel. The number of channel hollows was determined on the lower and upper sections of these main channels. It can be stated that the average shape of the main channel calculated to its total length depends on the density of the tributary channels and on the distance of tributary channels from each other. The main channel shape is smaller if less water flows on the floor for a long time because of the small density of the tributary channels and the great distance between the tributary channels. In this case, the channel deepens, but it does not widen. The width of the main channel depends on the number and location of the rivulets developing on channel-free relief. The main channel becomes narrow towards its lower end if the tributary rivulets are denser and longer on the upper part of the main rivulet developing on the channel-free, plain terrain and their distance is larger compared to the lower end. The channel hollows develop mainly at those places where the later developing tributary channels are hanging above the floor of the main channel. Thus, the former ones are younger than the latter ones. It can be stated that the morphology of the main channels (shape, channel hollows, and width changes of the main channel) is determined by the tributary channels (their number, location and age).
Copyright © by EnPress Publisher. All rights reserved.