Currently there is a great acceptance in medicine and dentistry that clinical practice should be “evidence-based” as much as possible. That is why multiple works have been published aimed at decreasing radiation doses in the different types of imaging modalities used in dentistry, since the greater effect of radiation, especially in children, forces us to take necessary measures to rationalize its use, especially with Cone Beam computed tomography (CBCT), the method that provides the highest doses in dentistry. This review was written using such an approach with the purpose of rationalizing the radiation dose in our patients. In order to formulate recommendations that contribute to the optimization of the use of ionizing radiation in dentistry, the SEDENTEXCT project team compiled and analyzed relevant publications in the literature, guidelines that have demonstrated their efficiency in the past, thus helping to see with different perspectives the dose received by patients, and with this, it is recommended taking into account this document so as to prescribe more adequately the complementary examinations that we use on a daily basis.
Infrared thermal imaging technology is another new branch for medical imaging after traditional medical imaging technologies such as X-ray, ultrasound and magnetic resonance (MRI). It has the advantages of noninvasive, nondestructive, simple and fast. Its application can radiate multiple clinical departments. This paper mainly expounds the principle, influencing factors of medical infrared thermography and its application in radiation protection and other medical fields.
The micro staring hyperspectral imager can simultaneously acquire two spatial and one spectral images, and only record the external orientation elements of the entire hyperspectral image rather than the external orientation elements of each frame of the image, which avoids the geometric instability during scanning, effectively solves the problem of large geometric deformation of the small line scanning hyperspectral imager, and is suitable for the small UAV load platform with unstable attitude. At present, most of the research focuses on the radio-metric correction method of line scan hyperspectral imager. The application time of staring hyperspectral imager is short, and there is no mature data processing re-search at home and abroad, which hinders the application of UAV micro staring hyperspectral imaging system. In this paper, the calibration method of the linearity and variability of the radiation response of the micro staring hyperspectral imager on the UAV is studied, and the effectiveness of this method is quantitatively evaluated. The results show that the hyperspectral image has obvious vignetting effect and strip phenomenon before the correction of radiation response variability. After the correction, the radiation response variation coefficient of pixels in different bands decreases significantly, and the vignetting effect and image strip decrease significantly. In this paper, a multi-target radiometric calibration method is proposed, and the accuracy of radiometric calibration is verified by comparing the calibrated hyperspectral image spectrum with the measured ground object spectrum of the ground spectrometer. The results show that the calibration results of the multi-target radiometric calibration method show better results, especially for the near-infrared band, and the difference with the surface reflectance measured by the spectrometer is small.
Copyright © by EnPress Publisher. All rights reserved.