One of the core problems in soil erosion research is the estimation of soil erosion. It is a feasible method and technical approach to estimate soil erosion in Loess Plateau region by using USLE model, GIS and RS technology and using DEM data, meteorological data and land-use type data. With the support of GIS and RS technology, the USLE factors and soil erosion in Loess Plateau region were estimated, and the soil erosion intensity was classified according to the Chinese soil erosion intensity classification standard. The results can provide reference for the development of soil erosion control measures in the Loess Plateau.
Using the rank scale rule, taking 47 major port cities in China from 2001 to 2015 as research samples, this paper discusses the rank scale characteristics and hierarchical structure of coastal port city system from a multi-functional perspective, and divides the coupling type of multi-functional development based on shipping logistics. The research shows that: 1) from 2001 to 2015, the scale-free area of manufacturing function order scale distribution in the coastal port city system appeared bifractal structure, the hierarchical segmentation characteristics appeared, and the other functions were single fractal; From the perspective of long-term evolution, only the order and scale distribution of shipping logistics function has developed from centralization to equilibrium, while the business function, manufacturing function (scale-free region I), modern service function and population distribution function are in a centralized situation. 2) The hierarchical structure of coastal port city system has gradually changed from pyramid structure to spindle structure, and generally formed five levels: national hub, regional hub, regional sub center, regional node and local node. 3) From the perspective of multi-functional coupling types, the traditional functions of port cities are generally ahead, while the high-end service functions lag behind, and the improvement speed of urban functions is slow and tends to be flat, indicating that the multi-functional development of China’s coastal port cities is still at a low level, and the industrial system structure needs to be further optimized. 4) From the perspective of port cities at different levels, the functions of regional hub cities and regional sub central cities are in the stage of rapid growth; regional and local node cities are still in the growth stage of traditional functions such as industry and commerce.
Many questions of control theory are well studied for systems which satisfy to the relative degree definition. If this definition is fulfilled then there exists linear state-space transform reducing system to a very convenient canonical form where zero dynamics is a part of system’s equations. Algorithms of such reduction are well-known. However, there exist systems which don’t satisfy this definition. Such systems are the subject of investigation in the presented paper. To investigate their properties here we suggest to consider an analogue of the classical relative degree definition – the so-called column-wise relative degree. It turned out that this definition is satisfied in some cases when classical relative degree doesn’t exist. We introduce this notion here, investigate it properties and suggest algorithm for reducing systems to the column-wise relative degree compliant form if possible. It is possible to show that systems with column-wise relative degree also can be reduced to a convenient canonical form by a linear state-space transformation. Some problems arise from the fact that some systems which do not have relative degree can be reduced to a form with it using linear inputs or outputs transform. Here we show that this is an interesting mathematical problem, which can be solved with the help of properties of relative degree, formulated and proved in this paper.
In casting industries, issue of spent molding sand disposal is the origin of molding sand reclamation. Among from all reclamation concepts the thermal reclamation method is better for no-bake sand system. This study focuses on the evaluation of sand quality by considering physical and chemical characteristics of molding sand, which is reclaimed by thermal reclamation method. Electric fuel and fluidization mechanism is used in thermal reclamation system. Effect of reclamation temperature, soaking period and sand quantity on % reclamability, grain size, ADV and on LOI is investigated. The average grain size, low ADV, low LOI and acceptable % reclamability of thermally reclaimed sand are studied.
In recent years, the foundry sector has been showing an increased interest in reclamation of used sands. Grain shape, sieve analysis, chemical and thermal characteristics must be uniform while molding the sand for better casting characteristics. The problem that tackled by every foundry industry is that of processing an adequate supply of sand which has the properties to meet many requirements imposed upon while molding and core making. Recently, fluidized bed combustors are becoming core of ‘clean wastes technology’ due to their efficient and clean burning of sand. For proven energy efficient sand reclamation processing, analysis of heating system in fluidized bed combustor (FBC) is required. The objective of current study is to design heating element and analysis of heating system by calculation of heat losses and thermal analysis offluidized bed combustorfor improving efficiency.
The regulation of compressor extraction and energy storage can improve the performance of gas turbine energy system. In order to make the gas turbine system match the external load more flexibly and efficiently, a gas turbine cogeneration system with solar energy coupling compressor outlet extraction and energy storage is proposed. By establishing the variable condition mathematical model of air turbine, waste heat boiler and solar collector, we use Thermoflex software to establish the variable condition model of gas turbine compressor outlet extraction, and analyze the variable condition of the coupling system to study the changes of thermal parameters of the system in the energy storage, energy release and operation cycle. Taking the hourly load of a hotel in South China as an example, this paper analyzes the case of the cogeneration system of solar energy coupling compressor outlet extraction and energy storage, and compares it with the benchmark cogeneration system. The results show that taking a typical day as a cycle, the primary energy utilization rate of the system designed in this paper is 3.2% higher than that of the traditional cogeneration system, and the efficiency is 2.4% higher.
Copyright © by EnPress Publisher. All rights reserved.