In order to promote the application of noise map in high-speed railway noise management, the high-speed railway noise map drawing technology based on the combination of noise prediction model and geographic information system (GIS) is studied. Firstly, according to the distribution characteristics of noise sources and line structure characteristics of high-speed railway, the prediction model of multi equivalent sound sources and the calculation method of sound barrier insertion loss of high-speed railway are optimized; secondly, a three-dimensional geographic information model of a high-speed railway is built in GIS software, and the railway noise prediction technology based on the model is developed again; then, the noise of discrete nodes is calculated, and the continuous noise distribution map is drawn by spatial interpolation. The research results show that the comparison error between the noise map of a high-speed railway drawn by this technology and the measured results is less than 1 dB (A), which verifies the accuracy and practicality of the high-speed railway noise map, and can be used as a reference for the railway noise management department to formulate noise control countermeasures.
Ecological environment damage events will destroy or damage the balance between animal and plant habitats and ecosystems, and even pose a threat to China’s ecological security. However, at present, there are some problems in the identification and evaluation of forest ecosystem damage, such as imperfect evaluation system, insufficient quantitative evaluation methods, imperfect damage compensation management system, and lack of analysis of the overall damage of the interaction between human activities and forest ecosystem. Based on the damaged object, the system involves a total of four first-class indicators, including physical damage, mental damage, economic forest fruit loss, forest by-products loss, processing and manufacturing loss, forest tourism loss, scientific research literature and history loss, soil conservation loss, water conservation loss, wind prevention and sand fixation loss, carbon fixation and oxygen release loss, atmospheric purification loss. There are 14 secondary indicators of emergency treatment fee and investigation and evaluation fee, as well as 22 tertiary indicators, and the value quantification method of each indicator is clarified by using market value method, alternative cost method, shadow engineering method, recovery cost method and other methods. The article also discusses the management system of forest ecosystem damage from the two aspects of forestry technology department and judicial administration department. The purpose is to provide reference for the quantification and standardization of forest ecosystem damage assessment technology and the improvement of management system.
The national park with Chinese characteristics is the highest level of protection of a kind of natural protection, its establishment marks the park will implement the strictest ecological protection means. It is of great value to construct the utilization system of national park resources under the new natural protected area system in the new era to avoid the misunderstanding of “ecological protection only” and explore how to carry out the sustainable utilization of resources in the reform of national park system and mechanism. According to the analytic hierarchy process (AHP) and Delphi method, the evaluation framework, indicators, reference standards and weights of resource utilization under the national park system were determined in combination with the requirements of constructing the protected natural area system and the total value of resource ecosystem services (including harvest value, existence value and future value). Based on the application research of Bawangling zone of Hainan Tropical Rainforest National Park, the optimal resource utilization system in the future was proposed, and two optimization strategies of ecological adjustment of resource utilization system and construction of suitable resource utilization system were put forward.
Over several centuries, the native vegetation of the flat part of the Bogotá Savanna has been almost completely replaced by crops, pastures and urbanization. The last remnant of this vegetation is a small forest (10 hm2), located at Hacienda Las Mercedes on the northern edge of the city of Bogotá. The reduced size and isolation of the forest, aggravated by the uncontrolled growth of invasive vegetation (lianas and wild blackberry) has resulted in the loss of many species. However, in recent years the forest has been subject to rehabilitation actions and currently the area is immersed in a reserve where more extensive restoration programs are planned. In order to evaluate changes in the bird community to estimate the effects of restoration actions, the avifauna present in 2001–2002 and in 2014 was recorded by visual and auditory records at fixed points in the forest. Twenty-seven forest species were found in the first census and 30 in the second, and the relative abundances of at least a third of them also increased over the 13 years, indicating a positive result in the recovery of the forest. The results highlight the recovery capacity of the degraded ecosystems and the importance of continuing with restoration actions in the reserve area.
The study of the performance of high-efficiency heat pump systems has been a hot issue of general interest in the field of heat pump air conditioning. For the designed and developed two-stage casing tandem heat exchanger of heat pump system, the 3D finite volume method and the realizable k-ε model are used to numerically analyze the influence law of inlet fluid temperature and flow velocity on the overall heat transfer coefficient as well as the Nussle number of inner and outer tubes. The results show that decreasing the inlet water temperature or increasing the inlet refrigerant temperature can improve the overall heat transfer performance; Nuin increases with the increase of water and refrigerant flow rates, while Nuout increases with the increase of water flow rate but decreases with the increase of refrigerant flow rate; Nuin and Nuout both increase with the decrease of water temperature or refrigerant temperature increases.
Copyright © by EnPress Publisher. All rights reserved.