Introduction: In Colombia, the last oral health study showed that about 70% of the population has partial edentulism while 5.2% will have lost all their teeth between the age of 65 and 79. Rehabilitation with implants is an increasingly used option, which requires clinical and radiographic follow-up. Panoramic radiography is a low-cost option, in which it is possible to observe areas of bone loss, mesiodistal angulation of the implant, relationship with anatomical structures and lesions suggestive of peri-implantitis. Reports and analysis of relevant data on radiographic findings associated with dental implants are required to determine the risk factors for their success in patients who use them. Objective: To determine the prevalence and characterize the findings associated with osseointegration implants in panoramic radiographs. Methods: A descriptive cross-sectional observational study was carried out with 10,000 digital panoramic radiographs selected by convenience from radiological centers in the city of Bogota, Colombia, of which 543 corresponded to the sample analyzed for the presence of implants. The following were evaluated for each implant: location, position, angulation and distances to adjacent structures, using the Clínicalview® program (Orthopantomograph OP200D, Instrumentarium, USA). Results: The frequency of radiographs with implants was 5.43% with a total of 1,791 implants, with an average of 3.2 per radiograph. They were found in greater proportion in the upper jaw with a supracrestal location and an angulation of 10.3 degrees. 32% had implant/tooth or implant/implant distances that were less than optimal. 40.9% were restored and 1.2% showed lesions compatible with periimplantitis. Conclusions: A high percentage of the implants reviewed have a risk factor that affects their long-term viability, either due to angulation, supracrestal or crestal position, proximity to teeth or other implants, or because they are not restorable.
Imaging technology plays a key role in guiding endovascular treatment of aortic aneurysm, especially in the complex thoracoabdominal aorta. The combination of high quality images with a sterile and functional environment in the surgical suite can reduce contrast and radiation exposure for both patient and operator, in addition to better outcomes. This presentation aims to describe the current use of this technique, combining angiotomography and intraoperative cone beam computed tomography, image “fusion” and intravascular ultrasound, to guide procedures and thus improve the intraoperative success rate and reduce the need for reoperation. On the other hand, a procedure is described to create customized 3D templates with the high-definition images of the patient’s arterial anatomy, which serve as specific guides for making fenestrated stents in the operating room. These customized fenestration templates could expand the number of patients with complex aneurysms treated minimally invasively.
Based on the characteristics of liquid lens sparse aperture imaging, a radiative multiplet array structure is proposed; a simplified model of sparse aperture imaging is given, and the analytical expression of the modulation transfer function is derived from the optical pupil function of the multiplet array structure; the specific distribution form of this multiplet array structure is given, and the structure parameters are approximated by the dimensionless method; the two types of radiative multiplet array structures are discussed, and the filling factor, redundancy, modulation transfer function and other characteristic parameters are calculated. The physical phenomena exhibited by the parametric scan are discussed, and the structural features and imaging characteristics of these two arrays are compared. The results show that the type-II structure with larger actual equivalent aperture and actual cutoff frequency and lower redundancy is selected when the average modulation transfer function and the IF characteristics of the modulation transfer function of the two structures are close to each other; the type-II structure has certain advantages in imaging; the conclusion is suitable for arbitrary enclosing circle size because the liquid lens-based multiplet array structure adopts dimensionless approximation parameters; compared with the composite toroidal structure, the radiative multiplet mirror structure has a larger actual cut-off frequency and actual equivalent aperture when the filling factor is the same.
A metakaolin-based geopolymer was fabricated with 5 ratios of two different nanomaterials. On the one hand, silicon carbide nanowhiskers and, on the other hand, titanium dioxide nanoparticles. Both were placed in water and received ultrasonic energy to be dispersed. The effects on mechanical properties and reaction kinetics were analyzed. Compared to the reference matrix, the results showed a tendency to increase the flexural strength. Probably due to the geometry of the SiC nanowhiskers and the pore refinement by the nano-TiO2 particles. The calorimetry curves showed that incorporating TiO2 nanoparticles resulted in a 92% reduction in total heat, while SiC nanowhiskers produced a 25% reduction in total heat.
Root turnover is a key process of terrestrial ecosystem carbon cycle, which is of great significance to the study of soil carbon pool changes and global climate change. However, because there are many measurement and calculation methods of root turnover, the results obtained by different methods are quite different, and the current research on root turnover of forest ecosystem on the global regional scale is not sufficient, so the change law of root turnover of global forest ecosystem is still unclear. By collecting literature data and unifying the calculation method of turnover rate, this study integrates the spatial pattern of fine root turnover of five forest types in the world, and obtains the factors affecting fine root turnover of forest ecosystem in combination with soil physical and chemical properties and climate data. The results showed that there were significant differences in fine root turnover rate among different forest types, and it gradually decreased with the increase of latitude; the turnover rate of fine roots in forest ecosystem is positively correlated with annual average temperature and annual average precipitation; fine root turnover rate of forest ecosystem is positively correlated with soil organic carbon content, but negatively correlated with soil pH value. This study provides a scientific basis for revealing the law and mechanism of fine root turnover in forest ecosystem.
Aiming at the problem of incompatibility of biomass models of forest organs, taking Chinese fir in Fujian Jiangle State-owned Forest Farm as the research object, based on selecting the optimal independent model of each organ, the biomass compatibility model of Chinese fir was established with a three-level joint control scheme. The results show that the compatibility equation system based on the whole plant biomass can effectively solve the problem of incompatibility in the whole plant biomass, each sub-biomass and between sub-biomass. Besides, except for the leaf biomass model, all other biomass models have good fitting effect, which is of great significance to the guidance of the analysis of local Chinese fir biomass.
Copyright © by EnPress Publisher. All rights reserved.