Introduction: Given the heterogeneous nature and inherent complexity of forensic medical expertise, the expert (medical professional or related areas) must make the best use of the technical and technological tools at his disposal. Imaging, referring to the set of techniques that allow obtaining images of the human body for clinical or scientific purposes, in any of its techniques, is a powerful support tool for establishing facts or technical evidence in the legal field. Objective: To analyze the use of magnetic resonance and computed tomography in postmortem diagnosis. Methodology: information was searched in the databases PubMed, Science Direct, Springer Journal and in the search engine Google Scholar, using the terms “X-Ray Computed Tomography”, “Magnetic Resonance Spectroscopy”, “Autopsy” and “Forensic Medicine” published in the period 2008–2015. Results: MRI is useful for the detailed study of soft tissues and organs, while computed tomography allows the identification of fractures, calcifications, implants and trauma. Conclusions: In the reports found in the literature search, regarding the use of nuclear magnetic resonance and computed tomography in postmortem cases, named by the genesis of the trauma, correlation was found between the use of imaging and the correct expert diagnosis at autopsy.
The micro staring hyperspectral imager can simultaneously acquire two spatial and one spectral images, and only record the external orientation elements of the entire hyperspectral image rather than the external orientation elements of each frame of the image, which avoids the geometric instability during scanning, effectively solves the problem of large geometric deformation of the small line scanning hyperspectral imager, and is suitable for the small UAV load platform with unstable attitude. At present, most of the research focuses on the radio-metric correction method of line scan hyperspectral imager. The application time of staring hyperspectral imager is short, and there is no mature data processing re-search at home and abroad, which hinders the application of UAV micro staring hyperspectral imaging system. In this paper, the calibration method of the linearity and variability of the radiation response of the micro staring hyperspectral imager on the UAV is studied, and the effectiveness of this method is quantitatively evaluated. The results show that the hyperspectral image has obvious vignetting effect and strip phenomenon before the correction of radiation response variability. After the correction, the radiation response variation coefficient of pixels in different bands decreases significantly, and the vignetting effect and image strip decrease significantly. In this paper, a multi-target radiometric calibration method is proposed, and the accuracy of radiometric calibration is verified by comparing the calibrated hyperspectral image spectrum with the measured ground object spectrum of the ground spectrometer. The results show that the calibration results of the multi-target radiometric calibration method show better results, especially for the near-infrared band, and the difference with the surface reflectance measured by the spectrometer is small.
Introduction: Stenoses in the path of arteriovenous fistulas (AVF) for hemodialysis are a very prevalent problem and there is long experience in their treatment by percutaneous angioplasty (PTA). These procedures, however, involve non-negligible equipment requirements, exposure to radiation and intravenous contrast that are not beneficial for the patient and make their performance more complex. This study reviews our initial experience with Doppler ultrasound-guided angioplasty. Methods: Prospective cohort of patients with native AVF dysfunction due to significant venous stenosis treated by Doppler echo-guided PTA. AVF puncture, lesion catheterization, balloon localization and inflation, and outcome verification were performed under ultrasound guidance. Only one fistulography was performed before and another one after dilatation. As a control, the cases performed during the same period by the usual angiographic method were also collected. Results: Between February 2015 and September 2018, 51 PTAs were performed on native AVF, of which 27 were echogenic (mean age, 65.3 years; 63% male). The technical success rate was 96%. In 26% of cases, PTA was repeated due to residual stenosis after angiographic imaging. There were 7.3% periprocedural complications. 92% of the AVFs were punctured at 24 hours. Primary patency at 1 month, 6 months and 1 year was 100%, 64.8% and 43.6%, and assisted patency was 100%, 87.2% and 74.8%. There were no significant differences in immediate or late results with respect to angiographically guided AVF angioplasty. Conclusions: AVF-PTA can be performed safely and effectively guided by Doppler ultrasound, which simplifies the logistics required for its performance, although we still need to improve the capacity for early verification of the result with this imaging technique.
Imaging technology plays a key role in guiding endovascular treatment of aortic aneurysm, especially in the complex thoracoabdominal aorta. The combination of high quality images with a sterile and functional environment in the surgical suite can reduce contrast and radiation exposure for both patient and operator, in addition to better outcomes. This presentation aims to describe the current use of this technique, combining angiotomography and intraoperative cone beam computed tomography, image “fusion” and intravascular ultrasound, to guide procedures and thus improve the intraoperative success rate and reduce the need for reoperation. On the other hand, a procedure is described to create customized 3D templates with the high-definition images of the patient’s arterial anatomy, which serve as specific guides for making fenestrated stents in the operating room. These customized fenestration templates could expand the number of patients with complex aneurysms treated minimally invasively.
Based on the characteristics of liquid lens sparse aperture imaging, a radiative multiplet array structure is proposed; a simplified model of sparse aperture imaging is given, and the analytical expression of the modulation transfer function is derived from the optical pupil function of the multiplet array structure; the specific distribution form of this multiplet array structure is given, and the structure parameters are approximated by the dimensionless method; the two types of radiative multiplet array structures are discussed, and the filling factor, redundancy, modulation transfer function and other characteristic parameters are calculated. The physical phenomena exhibited by the parametric scan are discussed, and the structural features and imaging characteristics of these two arrays are compared. The results show that the type-II structure with larger actual equivalent aperture and actual cutoff frequency and lower redundancy is selected when the average modulation transfer function and the IF characteristics of the modulation transfer function of the two structures are close to each other; the type-II structure has certain advantages in imaging; the conclusion is suitable for arbitrary enclosing circle size because the liquid lens-based multiplet array structure adopts dimensionless approximation parameters; compared with the composite toroidal structure, the radiative multiplet mirror structure has a larger actual cut-off frequency and actual equivalent aperture when the filling factor is the same.
Objective: to determine the diagnostic performance of magnetic resonance hysterosalpingography (HSG-MRI), using laparoscopy as the reference method. Materials and methods: 22 patients were included. All underwent HSG-MRI with a 1.5 Tesla resonator and then laparoscopy with chromotubation. Two radiologists examined the MRIs, determining tubal patency by consensus. Descriptive and diagnostic performance analyses were performed. Results: HSG-MRI had a success rate of 91%. Study duration was 49 ± 15 minutes, volume injected 26 ± 16 cm3 and pain scale 30 ± 19 out of 100. Sensitivity and specificity of HSG-MRI were 100% for global and left Cotte test, and 25% and 93.3% for right Cotte test, respectively. There were 2 minor complications and no major complications. Discussion: our initial results demonstrated high sensitivity and specificity. Although other studies analyzed the ability of HSG-MRI to assess tubal patency with good results, the use of a flawed reference standard left room for reasonable doubt, preventing a recommendation based on solid evidence. However, when comparing our results with those published, we observed a high degree of concordance insofar as the positive effusion is correctly diagnosed with a specificity of 100% or with a percentage close to this figure.
Copyright © by EnPress Publisher. All rights reserved.