Urbanization plays a crucial role in facilitating the integration of population growth, industrial development, economic expansion, and energy consumption. In this paper, we aim to examine the relationships between CO2 emissions and various factors including economic growth, urbanization, financial development, and energy consumption within Pakistan’s building sector. The study utilizes annual data spanning from 1990 to 2020. To analyze the cointegration relationship between these variables, we employ the quantile autoregressive distributed lag error correction model (QARDL-ECM). The findings of this research provide evidence supporting the presence of an asymmetric and nonlinear long-term relationship between the variables under investigation. Based on these results, we suggest the implementation of tariffs on nonrenewable energy sources and the formulation of policies that promote sustainable energy practices. By doing so, policymakers and architects can effectively contribute to minimising environmental damage. Overall, this study offers valuable insights that can assist policymakers and architects in making informed decisions to mitigate environmental harm while fostering sustainable development.
The CO2 heat pump air conditioning system of new energy vehicle is designed, and the vehicle model of CO2 heat pump module and heat management system is established based on KULI simulation. The effects of refrigerant charge, running time and compressor speed on the heat pump air conditioning system is studied, and the energy consumption is compared with the PTC heating system and the CO2 heat pump air conditioning system without waste heat recovery. The results show that the optimal charge for full-service operation is 750 g; increasing the compressor speed can increase the cooling capacity, so that the refrigerant temperature in the passenger compartment and battery inlet can quickly reach the appropriate temperature, but the COP<sub>h</sub>, COP<sub>c</sub> are reduced by 2.5% and 1.8% respectively. By comparing it with PTC heating and CO2 heat pump air conditioning systems without waste heat recovery, it is found that the energy consumption of this system is only for the PTC heating systems 42.5%, without waste heat recovery carbon dioxide heat pump air conditioning system of 86.6%. It greatly saves energy, but also increased the waste heat recovery function, so that the system supply air temperature increased by 26%, improve passenger cabin comfort. This provides a reference for the future experimental research of CO2 heat pump air conditioning and heat management system.
Copyright © by EnPress Publisher. All rights reserved.