Lead sulfide (PbS) is an important IV-VI semiconductor material with narrow bandwidth and wide wave width, which attracts people's attention. Nano-level PbS has many novel optoelectronic properties and has a wide range of applications in the field of optoelectronics, such as infrared optoelectronic devices, photovoltaic devices, light-emitting devices and display devices. In this paper, Pbs is produced by solvent thermal method by using lead acetate as lead source, sulfur power as sulfur source, ethylene glycol as solvent, and acetic acid to provide acidic environment. The reaction acidity, type of lead source, amount of sulfur source and other aspects will be explored. The products obtained under different conditions were characterized by X-ray diffraction (XRD), optical microscopy and scanning electron microscopy (SEM). The results showed that PbS produced at 140°C for 24 hours, using 14mL ethylene glycol and 1.2mL acetic acid has the best morphology. It has a non-planar six-arm symmetrical structure. Finally, we prepare the lead sulfide composite Ni/PbS, and characterized it.
A novel composite material based on polymers (polyvinyl alcohol, polyvinyl butyral) and liquid crystal (4-n-pentyl-4’-cyanobiphenyl) has been developed and studied. Configuration transformations of point defects in nematic droplets under the influence of an electric field, caused by localized changes in the concentration of NLC within the polymer matrix, have been discovered and analyzed. The boundary conditions necessary for achieving a nematic structure with homogeneous alignment of the director both within the droplet and at its surface have been established, optimizing the anisotropy of light transmission in polymer-dispersed liquid crystal (PDLC) films. Additionally, polarization effects inside nematic droplets under the application of an electric field have been identified.
Integrating Education 4.0 in higher education necessitates a transformational leadership approach that champions innovation and technology adoption. This paper reviews the impact of transformational leadership in fostering a conducive environment for Education 4.0, emphasising personalised and technology-enhanced learning experiences. With their vision and motivational prowess, transformational leaders are crucial in steering educational institutions through digital transformation, encouraging the adoption of advanced technologies like artificial intelligence, virtual reality, and data analytics. These leaders are pivotal in nurturing a culture of continuous improvement and empowerment, actively involving team members in pursuing collective achievements and personal growth. The study highlights the importance of transformational leadership in addressing the dynamic challenges and opportunities presented by Education 4.0. By inspiring educators and students to embrace change, transformational leaders facilitate the integration of innovative teaching methods and technologies, enhancing learning outcomes and preparing students for the demands of the digital age. The findings suggest that transformational leadership is instrumental in creating a flexible, relevant, and forward-thinking educational environment that aligns with the objectives of Education 4.0. This paper advocates strategically emphasising the development of transformational leaders within academic institutions. Such leadership is essential for navigating the complexities of digital-area education, ensuring institutions remain adaptive and responsive to technological advancements, and equipping students with the necessary skills to thrive in a rapidly evolving landscape.
Modelling and simulation have now become standard methods that serve to cut the economic costs of R&D for novel advanced systems. This paper introduces the study of modelling and simulation of the infrared thermography process to detect defects in the hydroelectric penstock. A 3-D penstock model was built in ANSYS version 19.2.0. Flat bottom holes of different sizes and depths were created on the inner surface of the model as an optimal scenario to represent the subsurface defect in the penstock. The FEM was applied to mimic the heat transfer in the proposed model. The model’s outer surface was excited at multiple excitation frequencies by a sinusoidal heat flux, and the thermal response of the model was presented in the form of thermal images to show the temperature contrast due to the presence of defects. The harmonic approximation method was applied to calculate the phase angle, and its relationship with respect to defect depth and defect size was also studied. The results confirmed that the FEM model has led to a better understanding of lock-in infrared thermography and can be used to detect subsurface defects in the hydroelectric penstock.
Definitive diagnosis of Craniosynostosis (CS) with computed tomography (CT) is readily available, however, exposure to ionizing radiation is often a hard stop for parents and practitioners. Lowering head CT radiation exposure helps mitigate risks and improves diagnostic utilization. The purpose of the study is to quantify radiation exposure from head CT in patients with CS using a ‘new’ (ultra-low dose) protocol; compare prior standard CT protocol; summarize published reports on cumulative radiation doses from pediatric head CT scans utilizing other low-dose protocols. A retrospective study was conducted on patients undergoing surgical correction of CS, aged less than 2 years, between August 2014 and February 2022. Cumulative effective dose (CED) in mSv was calculated, descriptive statistics were performed, and mean ± SD was reported. A literature search was conducted describing cumulative radiation exposure from head CT in pediatric patients and analyzed for ionizing radiation measurements. Forty-four patients met inclusion criteria: 17 females and 27 males. Patients who obtained head CT using the ‘New’ protocol resulted in lower CED exposure of 0.32 mSv ± 0.07 compared to the prior standard protocol at 5.25 mSv ± 2.79 (p < 0.0001). Five studies specifically investigated the reduction of ionizing radiation from CT scans in patients with CS via the utilization of low-dose CT protocols. These studies displayed overall CED values ranging from 0.015 mSv to 0.77 mSv. Our new CT protocol resulted in 94% reduction of ionizing radiation. Ultra-low dose CT protocols provide similar diagnostic data without loss of bone differentiation in CS and can be easily incorporated into the workflow of a children’s hospital.
Objective: To evaluate the imaging features of spondyloarthritis on magnetic resonance imaging (MRI) of the sacroiliac (SI) joints in terms of topography (in thirds) and affected margin, since this aspect is rarely addressed in the literature. Methods: Cross-sectional study with MRI (1.5 T) evaluation of the SI in 16 patients with diagnosis of axial spondyloarthritis regarding the presence of acute (subchondral bone edema, enthesitis, synovitis and capsulitis) and chronic changes (erosions, subchondral bone sclerosis, bone bridging and fatty replacement), performed by two radiologists, blinded to clinical data. MRI findings were correlated with clinical data including age, disease duration, medications, HLA-B27, BASDAI, ASDAS-VHS and ASDAS-PCR, BASMI, BASFI, and mSASSS. Results: Bone edema pattern and erosions showed predominance in the upper third of SI (p = 0.050, p = 0.0014, respectively). There was a correlation between the time of disease and structural changes by affected third (p = 0.028-0.037), as well as the presence of bone bridges with BASMI (p = 0.028) and mSASSS (p = 0.014). Patients with osteitis of the lower third had higher ASDAS values (ESRV: p = 0.011 and CRP: p = 0.017). Conclusion: Chronic inflammatory changes and the pattern of bone edema predominated in the upper third of the SI, but there was also concomitant involvement of the middle or lower thirds of the joint. The localization of involvement in the upper third of the SI was insufficient to differentiate between degeneration and inflammation.
Copyright © by EnPress Publisher. All rights reserved.