The major objective of this research paper is to assess the management effectiveness of Sheikh Badin National Park District Dera Ismail Khan Khyber Pakhtunkhwa, Pakistan with respect to tourist’s satisfaction. A sample size of 389 respondents (local community, wildlife staff, tourists) were selected through simple random sampling to conclude respondents’ attitude towards phenomenon investigated through three-level Likert scale as a measurement tool. Association between a dependent variable (management effectiveness) was assessed on the independent variables (tourist satisfaction) through a chi-square test. Association of management effectiveness was highly significant with tourists satisfaction from promos of park (p = 0.000), access to information (p = 0.000), roads network (p = 0.000), residential facilities (p = 0.000), trained guides (p = 0.000), safety from crimes and criminals (p = 0.000), provision of health and security services (p = 0.000), overall satisfaction of tourists (p = 0.000), recommendation of SBNP to other tourists (p = 0.000) and revisit intentions of tourists (p = 0.000). Improvement in security measures, better advertisement and improvement in park infrastructure were major recommendations considering the study.
In this study, robust and defect-free thin film composite (TFC) forward osmosis (FO) membranes have been successfully fabricated using ceramic hollow fibers as the substrate. Polydopamine (PDA) coating under controlled conditions is effective in reducing the surface pores of the substrate and making the substrate smooth enough for interfacial polymerization. The pure water permeability (A), solute permeability (B), and structural parameter (S) of the resultant FO membrane are 0.854 L·m–2·h−1·bar−1 (LMH/Bar), 0.186 L·m–2·h−1 (LMH), and 1720 µm, respectively. The water flux and reverse draw solute flux are measured using NaCl and proprietary ferric sodium citrate (FeNaCA) draw solutions at low and high osmotic pressure ranges. As the osmotic pressure increases, a higher water flux is obtained, but its increase is not directly proportional to the increase in the osmotic pressure. At the membrane surface, the effect of dilutive concentration polarization is much less serious for FeNaCA-draw solutions. At an osmotic pressure of 89.6 bar, the developed TFC membrane generates water fluxes of 11.5 and 30.0 LMH using NaCl and synthesized FeNaCA draw solutions. The corresponding reverse draw solute flux is 7.0 g·m–2·h−1 (gMH) for NaCl draw solution, but it is not detectable for FeNaCA draw solution. This means that the developed TFC FO membranes are defect-free and their surface pores are at the molecular level. The performance of the developed TFC FO membranes is also demonstrated for the enrichment of BSA protein.
Numerical study of subcooled and saturated flow boiling in the curved and helically coiled tubes in presence of phase change is one of the challenging area of CFD studies. In this paper, the CFD modeling of the nucleate and convective flow boiling in the small helically coiled tube at low vapor quality (up to the 18.93 percent) region is studied. A proper Eulerian-based mathematical model is used for interphase exchange forces and heat transfer between two phases in CFD modeling using Bulk boiling model. The results show that, the inner and the bottom wall of the helically coiled tube have the lowest and the highest heat transfer coefficient, respectively. The effect of change in coil diameter, helical pitch and tube diameter is investigated on the counters of vapor volume fraction. It is seen that at low vapor quality flows, the heat transfer coefficient is enhanced by decreasing in coil diameter, tube diameter and increasing in coil pitch of helically coiled tube.
Heat conduction theory stipulates that two thermo-physical properties of materials: the thermal conductivity “k” and the thermal diffusivity “α” influence the temperature evolution in regular and irregular bodies as a response to various cooling/heating conditions. The traditional statement involving the two thermo-physical properties is examined at length in the present study for the case of a semi-infinite region. The primary objective of the present study is to investigate the influence of the less known thermo-physical property called the thermal effusivity “e” on the incipient surface temperature rise in a semi-infinite body affected by uniform surface heat flux. The secondary objective of the study is to identify a key figure of merit named the dimensionless threshold time that separates the incipient temperature elevation in a semi-infinite region from the incipient temperature elevation in a large wall of finite thickness under the same uniform surface heat flux. The outcome of the methodical analysis suggests that the accurate estimate for the dimensionless threshold time τth in the semi-infinite region should be 0.10.
Copyright © by EnPress Publisher. All rights reserved.