The challenge of rural electrification has become more challenging today than ever before. Grid-connected and off-grid microgrid systems are playing a very important role in this problem. Examining each component’s ideal size, facility system reactions, and other microgrid analyses, this paper proposes the design and implementation of an off-grid hybrid microgrid in Chittagong and Faridpur with various load dispatch strategies. The hybrid microgrids with a load of 23.31 kW and the following five dispatch algorithms have been optimized: (i) load following, (ii) HOMER predictive, (iii) combined dispatch, (iv) generator order, and (v) cycle charging dispatch approach. The proposed microgrids have been optimized to reduce the net present cost, CO2 emissions, and levelized cost of energy. All five dispatch strategies for the two microgrids have been analyzed in HOMER Pro. Power system reactions and feasibility analyses of microgrids have been performed using ETAP simulation software. For both the considered locations, the results propound that load-following is the outperforming approach, which has the lowest energy cost of $0.1728/kWh, operational cost of $2944.13, present cost of $127,528.10, and CO2 emission of 2746 kg/year for the Chittagong microgrid and the lowest energy cost of $0.2030/kWh, operating cost of $3530.34, present cost of 149,287.30, and CO2 emission of 3256 kg/year for the Faridpur microgrid with a steady reaction of the power system.
Objective: To determine the presence of bacteria by means of microbiological analysis on the surfaces contacted by the operator during the taking and processing of intraoral radiographs at different times of the day in the Oral Radiology Service of the UPCH. Materials and methods: Nine surfaces of the oral radiology service were sampled. The samples were taken at two times by the same investigator; at the beginning and the end of the activities in the service, the surfaces were swabbed with Trypticase Soy Broth (TSB). The samples were inoculated and incubated in three culture media (Plate Count Agar, Lamb’s Blood Agar and Cetrimide Agar). Then the respective Colony Forming Unit (CFU) count was performed and Gram staining was also performed. Results: A high concentration of bacteria (4180 CFU/mL) and fungi was found in the oral radiology service. Gram-positive cocci were the most frequently found microorganisms and gram-negative bacilli were less frequently found. Conclusions: There is a high contamination of bacteria in the oral radiology service. When the activities are completed, the number of bacteria decreases, but the variety of bacteria increases.
Copyright © by EnPress Publisher. All rights reserved.