There are diverse effects in consequence of exposure to radiofrequency electromagnetic fields (RF-EMF). The interactions of fields and the exposed body tissues are related to the nature of exposure, tissue comportment, field strength and signal frequency. These interactions can crop different effects.
Magnetite magnetic nanoparticles (MNP) exhibit superparamagnetic behavior, which gives them important properties such as low coercive field, easy superficial modification and acceptable magnetization levels. This makes them useful in separation techniques. However, few studies have experimented with the interactions of MNP with magnetic fields. Therefore, the aim of this research was to study the influence of an oscillating magnetic field (OMF) on polymeric monolithic columns with vinylated magnetic nanoparticles (VMNP) for capillary liquid chromatography (cLC). For this purpose, MNP were synthesized by coprecipitation of iron salts. The preparation of polymeric monolithic columns was performed by copolymerization and aggregation of VMNP. Taking advantage of the magnetic properties of MNP, the influence of parameters such as resonance frequency, intensity and exposure time of a OMF applied to the synthesized columns was studied. As a result, a better separation of a sample according to the measured parameters was obtained, so that a column resolution (Rs) of 1.35 was achieved. The morphological properties of the columns were evaluated by scanning electron microscopy (SEM). The results of the chromatographic properties revealed that the best separation of the alkylbenzenes sample occurs under conditions of 5.5 kHz and 10 min of exposure in the OMF. This study constitutes a first application in chromatographic separation techniques for future research in nanotechnology.
This article explored mineral resources and their relation to structural settings in the Central Eastern Desert (CED) of Egypt. Integration of remote sensing (RS) with aeromagnetic (AMG) data was conducted to generate a mineral predictive map. Several image transformation and enhancement techniques were performed to Landsat Operational Land Imager (OLI) and Shuttle Radar Topography Mission (SRTM) data. Using band ratios and oriented principal component analysis (PCA) on OLI data allowed delineating hydrothermal alteration zones (HAZs) and highlighted structural discontinuity. Moreover, processing of the AMG using Standard Euler deconvolution and residual magnetic anomalies successfully revealed the subsurface structural features. Zones of hydrothermal alteration and surface/subsurface geologic structural density maps were combined through GIS technique. The results showed a mineral predictive map that ranked from very low to very high probability. Field validation allowed verifying the prepared map and revealed several mineralized sites including talc, talc-schist, gold mines and quartz veins associated with hematite. Overall, integration of RS and AMG data is a powerful technique in revealing areas of potential mineralization involved with hydrothermal processes.
Objective: To describe magnetic resonance imaging (MRI) findings of the brain in patients younger than 65 years who were studied by transcranial Doppler (TCD) with microbubble contrast, with a history of cryptogenic cerebrovascular accident (CVA) and suspected patent foramen ovale (PFO).
Materials and methods: This retrospective cross-sectional study included patients of both sexes, younger than 65 years of age.
Results: Our sample (n = 47.47% male and 53% female, mean age is 42 years) presented high-intensity transient signals (HITS) positive in 61.7% and HITS-negative in 38.3%. In HITS-positive patients, lesions at the level of the subcortical U-brains, single or multiple with bilaterally symmetrical distribution, predominated. In patients with moderate HITS, lesions in the vascular territory of the posterior circulation predominated.
Conclusion: In patients younger than 65 years with cryptogenic stroke and subcortical, single or multiple U-shaped lesions with bilateral and symmetrical distribution, a PFO should be considered as a possible cause of these lesions.
The changes the magnetic flux generated (electric, magnetic and electromagnetic waves) on the surface of earth due to sudden changes is a matter of discussion. These emissions occur along the fault line generated due to geological and tectonic processes. When sudden changes occur in the environment due to seismic and atmospheric variations, these sensing was observed by creatures and human bodies because the animals and trees adopt the abnormal signals and change the behavior. We have analyzed the changing behavior of recorded signal by live sensors (i.e., banyan tree). So we use the deep-rooted and long-aged banyan tree. The root of banyan tree (long-aged) has been working as a live sensor to record the geological and environmental changes. We record the low frequency signals propagated through solar-terrestrial environment which directly affect the root system of the banyan tree and changes that have been observed by live sensors. Then, very low frequency (VLF) signal may propagate to the earth-ionosphere waveguide. We have also analyzed the different parameters of live cells which is inbuilt in latex of the tree, so we record the dielectric parameters of green stem latex and found some parameters i.e., dielectric constant (ε) and dielectric loss (ε’) of various trees to verify these natural hazards and found good correlation. Therefore, we can say by regularly monitoring the bio-potential signal and dielectric properties of banyan tree and we are able to find the precursory signature of seismic hazards and environmental changes.
Magnetic graphene oxide nanocomposites (M-GO) were successfully synthesized by partial reduction co-precipitation method and used for removal of Sr(II) and Cs(I) ions from aqueous solutions. The structures and properties of the M-GO was investigated by X-ray diffraction, Fourier transformed infrared spectroscopy, X-ray photoelectron spectroscopy, transmission electron microscopy, scanning electron microscopy, vibrating sample magnetometer (VSM) and N2-BET measurements. It is found that M-GO has 2.103 mg/g and 142.070 mg/g adsorption capacities for Sr(II) and Cs(I) ions, respectively. The adsorption isotherm matches well with the Freundlich for Sr(II) and Dubinin–Radushkevich model for Cs(I) and kinetic analysis suggests that the adsorption process is pseudo-second-ordered.
Copyright © by EnPress Publisher. All rights reserved.