In order to meet the guidance, publicity and commercial functions, various types of billboards have become important permanent facilities in the airport terminal, which are distributed all over the terminal. The advertising materials inside billboards have certain fire hazards, and there is a lack of research on the fire risk of advertising materials at present. Therefore, it is necessary to study the fire risk of advertising materials in airport terminal. Taking PVC board, a commonly used advertising material, as the research object, Pyrosim was used to model and analyze its fire, and the characteristics of fire spread, smoke flow, and distribution of combustion products such as CO and CO2 in the terminal building were obtained. This study explores the fire combustion characteristics of advertising materials in civil airport terminals, providing a basis for fire prevention management in civil airport terminals.
Traditional building heating warms entire rooms, often leaving some dissatisfied with uneven warmth. Recently, the personalized heating system has addressed this by providing targeted warmth, enhancing comfort and satisfaction. The personalized heating system in this study is a new enclosed personalized heating system consisting of a semi-enclosed heating box and an insulated chair covered with a thick blanket. The study compares the heating effects of semi-enclosed and enclosed localized heating systems on the body and examined changes in subjects’ thermal sensations. Due to the lower heat loss of the enclosed personalized heating system compared to the semi-enclosed version, it created thermal micro-environments with higher ambient temperatures. The maximum air temperature increase within the enclosed system was twice that of the semi-enclosed system, with the heating film surface temperature rising by up to 6.87 ℃. Additionally, the temperature of the skin could increase by as much as 6.19 ℃, allowing individuals to maintain thermal neutrality even when the room temperature dropped as low as 8 ℃. A two-factor repeated measures analysis of variance revealed differences in temperature sensitivity across various body regions, with the thighs showing a notably higher response under high-power heating conditions. The corrective energy and power requirements of the enclosed personalized heating system also made it more energy-efficient than other personalized heating systems, with a minimum value reaching 6.07 W/K.
In order to understand the finishing effect of Waterborne Acrylic Paint under different painting methods and amount, bamboo-laminated lumber for furniture was coated with waterborne acrylic paint, then the effects of different painting methods and amount on the drying rate, smoothness, hardness, adhesion and wear resistance of the paint film were investigated. Further, the mechanism of film formation was described by thermal property analysis using thermogravimetry and differential scanning calorimeter. The results show that different painting methods have little effect on film properties, the drying time of primer and topcoat are not affected by them, which is 8/8.5 min for primer surface/solid and 6.5/7 min for topcoats. The film surface hardness and adhesion can reach B and 0 grade, the best wear resistance of the film is 51.24 mg·100 r−1 when using one-layer primer one-layer topcoat. Different coating amount has great influence on film properties, the drying speed of the film increases with the increase of the painting amount. The film properties reach the best when the painting amount is 80 g/m2, while too little painting amount leads to the decrease of hardness, and too much leads to the wear resistance weaken. Thermal analysis of the primer and topcoat show that water decomposition occurs at 100 ℃ and thermal decomposition of organic components occur at 350 ℃. Topcoats have better thermal stability than primers higher than that of topcoat, the topcoat displayed better thermal stability than the primer.
The interest in smart grids and new technologies is growing around the world. Countries are investing in the development of new technologies that will help achieve environmental goals, energy supply efficiency, improve energy efficiency and increase consumer involvement in the energy generation. One of such technology is a blockchain. It is believed that the blockchain, combined with a smart grid, provides an opportunity to integrate the activities of all stakeholders, including: generators, distributors and consumers of electricity. The aim of the article is to identify the key research areas discussed by the researchers of both the smart grid and the blockchain issues. An analysis of the Scopus database from 2015 to 2023 was conducted. Using a created bibliometric query, a systematic literature review was conducted. 476 scientific publications relating to the issues addressed were identified. Using the VOSviewer software, a bibliometric analysis was performed using the author’s keywords. The bibliometric maps obtained allowed for the identification of key research areas. The article also presents potential future directions of scientific considerations, which should be focused on the issue of green smart grid and green blockchain. The results presented in the article can inspire researchers looking for research gaps or describing the current state of knowledge in the field of the smart grid and the blockchain issues.
This research intends to find out the compliance acts based on the manufacturing industry of Bangladesh and lead to the development of the integrated theory of compliance model. There are several compliance regulations, that are separately dealt with in any manufacturing organization. These compliance regulations are handled at various ends of the organization making the process quite scattered, time-consuming, and tedious. To fix this problem, the integration of organizational compliance regulations is brought under one platform. Researchers have applied the qualitative approach with multiple case studies methodology scrutinizing the in-depth interviews and transcripts. Furthermore, the NVIVO tool has been used to analyze, where the necessary themes of the Organizational Compliance Regulations are found. Therefore, we have proposed a conceptual framework to inaugurate a standalone combined framework, which is an innovative and novel measure.
The COVID-19 pandemic had an adverse impact on the mental health of frontline workers including firefighters. To better understand this occurrence, this cross-sectional study evaluated the prevalence of depression, anxiety, and stress among 105 operational team and elite team firefighters in Kota Bharu, Kelantan State, Malaysia before and after the pandemic. The Depression, Anxiety and Stress Scale-21 (DASS-21), a validated self-reporting survey tool, was used to assess symptoms of depression, anxiety, and stress among the survey respondents. Findings revealed that firefighters had an increased level of anxiety and depression during the post-pandemic period compared to the pre-pandemic period. However, there was a decrease in the stress levels (20%) reported by study participants. Respondents belonging to the operational team had a higher reported level of depression, anxiety, and stress than those from the elite team. This may be attributed the operational team being more exposed to the risk of COVID-19 infection on account of their routine and more voluminous workload. The findings of this study suggest that firefighters, in general, are at an increased risk of mental health problems as a result of the COVID-19 pandemic. Knowing this, it is important to consider these findings when addressing the prevention and management of mental health among firefighters. This includes providing additional support and devoting more resources to those who are most at risk for experiencing symptoms of mental health such as firefighters performing functions aligned with that of an operational team.
Copyright © by EnPress Publisher. All rights reserved.