One-dimensional unsteady theoretical models of three different photovoltaic module installation modes are established. Through MATLAB modeling and simulation, the influence of photovoltaic modules on roof heat transfer in different layout modes is compared. Comparing with ordinary roof, the shading effect of photovoltaic roof in summer and heat preservation effect in winter was analyzed. The results show that the PV roof layout with ventilation channel is better in summer. The proof layout with closed flow channel is better in winter.
This paper is devoted to the discussion of dynamical properties of anisotropic dark energy cosmological model of the universe in a Bianchi type-V space time in the framework of scale covariant theory of gravitation formulated by Canuto et al.(phys.Rev.Lett.39:429,1977).A dark energy cosmological model is presented by solving the field equations of this theory by using some physically viable conditions. The dynamics of the model is studied by computing the cosmological parameters, dark energy density, equation of state(EoS) parameter, skewness parameters, deceleration parameter and the jerk parameter. This being a scalar field model gives us the quintessence model of the universe which describes a significant dark energy candidate of our accelerating universe. All the physical quantities discussed are in agreement with the recent cosmological observations.
Asian Infrastructure Investment Bank’s president Mr. Jin Liqun shares with JIPD Editor-in-Chief, Dr. Gu Qingyang, his passion for infrastructure finance, as he reflects upon his goal of steering an environmentally friend and corruption-free AIIB toward building social-impacting infrastructure across Asia.
From governmental departments to international financial institutes, Mr. Jin Liqun has undertaken almost every essential role in finance. With his vast experience across the private and public sectors, particularly in multilateral development banks, Mr. Jin Liqun currently serves as Asian Infrastructure Investment Bank (AIIB)’s first President since its founding in 2016, following a stint as Secretary-General of the Multilateral Interim Secretariat created to establish the bank. Beginning from his two decades of governmental experience at the Chinese Ministry of Finance, rising from the rank of Deputy Director General to Vice Minister, Mr. Jin was then called to serve as Vice President, and then Ranking Vice President, of the Asian Development Bank, and later as Alternate Executive Director for China at the World Bank and at the Global Environment Facility. Mr. Jin had also served as Chairman of China International Capital Corporation Ltd., China’s first joint-venture investment bank, in addition to serving as Chairman of the Supervisory Board of the sovereign wealth fund China Investment Corporation and as Chairman of the International Forum of Sovereign Wealth Funds.
In this paper, an improved mathematical model for flashover behavior of polluted insulators is proposed based on experimental tests. In order to determine the flashover model of polluted insulators, the relationship between conductivity and salinity of solution pollution layer of the insulator is measured. Then, the leakage of current amplitude of four common insulators versus axial, thermal conductivity and arc constants temperature was determined. The experimental tests show that top leakage distance (TLd) to bottom leakage distance (BLd) ratio of insulators has a significant effect on critical voltage and current. Therefore, critical voltage and current were modeled by TLd to BLd ratio Index (M). Also, salinity of solution pollution layer of the insulators has been applied to this model by resistance pollution parameter. On the other hand, arc constants of each insulator in new model have been identified based on experimental results. Finally, a mathematical model is intended for critical voltage against salinity of solution pollution layer of different insulators. This model depends on insulator profile. There is a good agreement between the experimental tests of pollution insulators obtained in the laboratory and values calculated from the mathematical models developed in the present study.
Helical deep hole drilling is a process frequently used in industrial applications to produce bores with a large length to diameter ratio. For better cooling and lubrication, the deep drilling oil is fed directly into the bore hole via two internal cooling channels. Due to the inaccessibility of the cutting area, experimental investigations that provide information on the actual machining and cooling behavior are difficult to carry out. In this paper, the distribution of the deep drilling oil is investigated both experimentally and simulatively and the results are evaluated. For the Computational Fluid Dynamics (CFD) simulation, two different turbulence models, i.e. the RANS k-ω-SST and hybrid SAS-SST model, are used and compared. Thereby, the actual used deep drilling oil is modelled instead of using fluid dynamic parameters of water, as is often the case. With the hybrid SAS-SST model, the flow could be analyzed much better than with the RANS k-ω-SST model and thus the processes that take place during helical deep drilling could be simulated with realistic details. Both the experimental and the simulative results show that the deep drilling oil movement is almost exclusively generated by the tool rotation. At the tool’s cutting edges and in the flute, the flow velocity drops to zero for the most part, so that no efficient cooling and lubrication could take place there. In addition, cavitation bubbles form and implode, concluding in the assumption that the process heat is not adequately dissipated and the removal of chips is adversely affected, which in turn can affect the service life of the tool and the bore quality. The carried out investigations show that the application of CFD simulation is an important research instrument in machining technology and that there is still great potential in the area of tool and process optimization.
Copyright © by EnPress Publisher. All rights reserved.