The temporomandibular joint (TMJ) is considered a bicondylar diarthrosis type joint. Imaging evaluation is a fundamental part of its assessment, which should include both bony and soft tissue characteristics and the relationship between them. Magnetic resonance imaging (MRI) represents the gold standard for the study of soft tissues; however, up to now, its main application continues to be the visualization of the articular disc. For this reason, the present article aimed to point out the information available in the literature regarding the visualization of the joint capsule in MRI and to evaluate it as an independent structure.
Gout is an arthritis characterized by the deposition of sodium monoacid crystals in the synovial membrane, articular cartilage, and periarticular tissues that leads to an inflamatory process. In most cases, the diagnosis is established by clinical criteria and analysis of the synovial fluid for MSU crystals. However, gout may manifest in atypical ways and make diagnosis difficult. In these situations, imaging studies play a fundamental role in helping to confirm the diagnosis or even exclude other differential diagnoses. Conventional radiography is still the most commonly used method in the follow-up of these patients, but it is a very insensitive test, because it only detects late changes. In recent years, advances in imaging methods have emerged in relation to gout. Ultrasound has proven to be a highly accurate test in the diagnosis of gout, identifying MSU deposits in articular cartilage and periarticular tissues, and detecting and characterizing tophi, tendinopathies, and tophi enthesopathies. Computed tomography is an excellent exam for the detection of bone erosions and evaluation of spinal involvement. Dual-energy computed tomography, a new method that provides information on the chemical composition of tissues, allows identification of MSU deposits with high accuracy. MRI can be useful in the evaluation of deep tissues not accessible by ultrasound. In addition to diagnosis, with the emergence of drugs that aim to reduce the tophaceous burden, imaging examinations become a useful tool in the follow-up treatment of gout patients.
Aiming at the current problems of poor dynamic reconstruction of UAV aerial remote sensing images and low image clarity, the dynamic reconstruction method of UAV aerial remote sensing images based on compression perception is proposed. Construct a quality reduction model for UAV aerial remote sensing images, obtain image feature information, and further noise reduction preprocessing of UAV aerial remote sensing images to better improve the resolution, spectral and multi-temporal trends of UAV aerial remote sensing images, and effectively solve the problems of resource waste such as large amount of sampled data, long sampling time and large amount of data transmission and storage. Maximize the UAV aerial remote sensing images sampling rate, reduce the complexity of dynamic reconstruction of UAV aerial remote sensing images, and effectively obtain the research requirements of high-quality image reconstruction. The experimental results show that the proposed dynamic reconstruction method of UAV aerial remote sensing images based on compressed sensing is correct and effective, which is better than the current mainstream methods.
In this study, the development of rinnenkarren systems is analyzed. During the field studies, 36 rinnenkarren systems were investigated. The width and depth were measured at every 10 cm on the main channels and then shape was calculated to these places (the quotient of channel width and depth). Water flow was performed on artificial rinnenkarren system. A relation was looked for between the density of tributary channels and the average shape of the main channel, between the distance of tributary channels from each other and the shape of a given place of the main channel. The density and total length of the tributary channels on the lower and upper sections of the main channels being narrow at their lower end (11 pieces) and being wide at their lower end (10 pieces) of the rinnenkarren systems were calculated as well as their average proportional distance from the lower end of the main channel. The number of channel hollows was determined on the lower and upper sections of these main channels. It can be stated that the average shape of the main channel calculated to its total length depends on the density of the tributary channels and on the distance of tributary channels from each other. The main channel shape is smaller if less water flows on the floor for a long time because of the small density of the tributary channels and the great distance between the tributary channels. In this case, the channel deepens, but it does not widen. The width of the main channel depends on the number and location of the rivulets developing on channel-free relief. The main channel becomes narrow towards its lower end if the tributary rivulets are denser and longer on the upper part of the main rivulet developing on the channel-free, plain terrain and their distance is larger compared to the lower end. The channel hollows develop mainly at those places where the later developing tributary channels are hanging above the floor of the main channel. Thus, the former ones are younger than the latter ones. It can be stated that the morphology of the main channels (shape, channel hollows, and width changes of the main channel) is determined by the tributary channels (their number, location and age).
Global energy agencies and commissions report a sharp increase in energy demand based on commercial, industrial, and residential activities. At this point, we need energy-efficient and high-performance systems to maintain a sustainable environment. More than 30% of the generated electricity has been consumed by HVAC-R units, and heat exchangers are the main components affecting the overall performance. This study combines experimental measurements, numerical investigations, and ANN-aided optimization studies to determine the optimal operating conditions of an industrial shell and tube heat exchanger system. The cold/hot stream temperature level is varied between 10 ℃ and 50 ℃ during the experiments and numerical investigations. Furthermore, the flow rates are altered in a range of 50–500 L/h to investigate the thermal and hydraulic performance under laminar and turbulent regime conditions. The experimental and numerical results indicate that U-tube bundles dominantly affect the total pumping power; therefore, the energy consumption experienced at the cold side is about ten times greater the one at the hot side. Once the required data sets are gathered via the experiments and numerical investigations, ANN-aided stochastic optimization algorithms detected the C10H50 scenario as the optimal operating case when the cold and hot stream flow rates are at 100 L/h and 500 L/h, respectively.
Copyright © by EnPress Publisher. All rights reserved.