Journal Browser
Search
Analytical equation for top heat loss coefficient of a vertical double-glazed flat plate collector
Suresh Kumar
Thermal Science and Engineering 2025, 8(4); https://doi.org/10.24294/tse10850
Submitted:11 Dec 2024
Accepted:12 Dec 2024
Published:29 Dec 2025
Abstract

A new method has been proposed to estimate top heat losses of vertical flat plate liquid/air collectors with double glazing. Empirical relations have been developed for the temperatures of glass covers, thus facilitating the calculation of individual heat transfer coefficients.  The values of individual heat transfer coefficients therefore obtained can be used in the proposed analytical equation for the estimation of the top heat loss coefficient of the vertical collector with double glazing.  The analytical equation has been developed for collector tilt angle of 60 to 90 degrees, plate temperature of 323 K to 423 K, absorber coating emittance of 0.1 to 0.95, air gap spacing of 20 mm to 50mm between the plate and inner glass cover, air gap spacing of 20 mm to 50mm between glass covers, wind heat transfer coefficient of 5 W/m2K to 30 W/m2K, and ambient temperature of 263K to 313K. The accuracy of the analytical equation has been validated for the said range of variables in comparison to numerical solutions, and the values of the top heat loss coefficient are found to be within 2.5 percent compared to numerical solutions.  

© 2025 by the EnPress Publisher, LLC. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.

Copyright © by EnPress Publisher. All rights reserved.

TOP