The world economy needs a growth-lifting strategy, and infrastructure financing seems to hold the key. Based on the New Structural Economics (Lin, 2010; 2012) we discuss the heterogeneity of capital focusing on the long-term versus short-term orientation (STO). Traditional neoliberalism assumes that capital is homogenous, complete capital account liberalization is “beneficial”. However, previous studies have found evidence of long-term orientation (LTO) in the culture of many Asian economies (Hofstede, 1991). In this exploratory paper, we suggest that the LTO can be considered a special endowment which, under certain circumstances, can be developed into a comparative advantage (CA) in patient capital. If these countries can turn their latent CA into a revealed CA in patient capital, and develop the ability to “package” profitable and non-profitable projects in meaningful ways, they would have a “revealed” competitive advantage in infrastructure financing. The ability to “package” public infrastructure and private services is one of the key institutional factors for success in overseas cooperation.
The optimized methodology and results of the new characterization in terms of dose and image quality of the X-ray system used in the main pediatric hemodynamics service in Chile are presented. In addition, scattered dose rate values at the operator’s eye level are reported for all acquisition modes available in different thicknesses of absorbent media and angiography. The characterization was performed according to the European DIMOND and SENTINEL protocols adapted to pediatric procedures. The air kerma at the entrance surface (ESAK) was measured and the image quality parameters signal-to-noise ratio (SNR) and a figure of merit (FOM) were calculated. The scattered dose rate was measured in personal dose equivalent units. The ESAK for fluoroscopic modes ranged from 0.2 to 35.6 μGy/image when passing from 4 to 20 cm of polymethyl methacrylate (PMMA). For the cine mode, these values ranged from 2.8 to 160.1 μGy/image. The values of the image quality parameters showed a correct system configuration, although abnormal values were observed in the medium fluoroscopic mode. As for the scattered dose rate at the level of the cardiologist’s eyes, the highest value is PMMA with a thickness of 20 cm, where the cine mode reached 9.41 mSv·h-1. The differences found from previous evaluations can be explained by the deterioration of the system and the change of one of the X-ray tubes.
The human brain has been described as a complex system. Its study by means of neurophysiological signals has revealed the presence of linear and nonlinear interactions. In this context, entropy metrics have been used to uncover brain behavior in the presence and absence of neurological disturbances. Entropy mapping is of great interest for the study of progressive neurodegenerative diseases such as Alzheimer’s disease. The aim of this study was to characterize the dynamics of brain oscillations in such disease by means of entropy and amplitude of low frequency oscillations from Bold signals of the default network and the executive control network in Alzheimer’s patients and healthy individuals, using a database extracted from the Open Access Imaging Studies series. The results revealed higher discriminative power of entropy by permutations compared to low-frequency fluctuation amplitude and fractional amplitude of low-frequency fluctuations. Increased entropy by permutations was obtained in regions of the default network and the executive control network in patients. The posterior cingulate cortex and the precuneus showed differential characteristics when assessing entropy by permutations in both groups. There were no findings when correlating metrics with clinical scales. The results demonstrated that entropy by permutations allows characterizing brain function in Alzheimer’s patients, and also reveals information about nonlinear interactions complementary to the characteristics obtained by calculating the amplitude of low frequency oscillations.
The present work shows an application of the Chan-Vese algorithm for the semi-automatic segmentation of anatomical structures of interest (lungs and lung tumor) in 4DCT images of the thorax, as well as their three-dimensional reconstruction. The segmentation and reconstruction were performed on 10 CT images, which make up an inspiration-expiration cycle. The maximum displacement was calculated for the case of the lung tumor using the reconstructions of the onset of inspiration, the onset of expiration, and the voxel information. The proposed method achieves appropriate segmentation of the studied structures regardless of their size and shape. The three-dimensional reconstruction allows us to visualize the dynamics of the structures of interest throughout the respiratory cycle. In the future, it is expected to have more evidence of the good performance of the proposed method and to have the feedback of the clinical expert, since the knowledge of the characteristics of anatomical structures, such as their dimension and spatial position, helps in the planning of Radiotherapy (RT) treatments, optimizing the radiation dose to cancer cells and minimizing it in healthy organs. Therefore, the information found in this work may be of interest for the planning of RT treatments.
In Costa Rica, there is no explicit recommendation from the competent authorities for the use of a specific phantom, so experts must explore what suppliers offer, among which the Normi Mam Digital phantom from PTW stands out. This article presents the results of the dosimetry and image quality control applied to the Normi Mam Digital phantom to validate it as equipment that complies with the recommendations of the Human Health Series No. 17. The results obtained were satisfactory, proving that the equipment complies with the tolerances recommended by international health bodies.
The integration of medical images is the process of registering and fusing them to obtain a greater amount of diagnostic information. In this work an analysis is performed for the integration of images obtained through computed axial tomography and magnetic resonance imaging, for which a tool was developed in the Matlab program, where the registration is implemented through equivalent features; in addition, the pairs of images are compared by several fusion rules, with a view to identify the best algorithm in which the resulting fused image contains the most information from the original representations.
Copyright © by EnPress Publisher. All rights reserved.