In recent years, ghost imaging has made important progress in the field of remote sensing imaging. In order to promote the application of solar ghost imaging in this field, this paper studies the computational ghost imaging based on the incoherent light of blackbody radiation. Firstly, according to the intensity probability density function of blackbody radiation, the expression of contrast-to-noise ratio (RCN) describing the quality of computational ghost imaging is obtained, and then the random speckle pattern simulating blackbody radiation is generated by computer with the idea of slice sampling, finally, a digital light projector is used to modulate and generate the random modulated light that simulates the blackbody radiation light source, and this light source is used to realize the computational ghost image of the reflective object in the experiment. The “ghost image” of the object under different measurement frame numbers is reconstructed, and the contrast-to-noise ratio describing the imaging quality is measured. The results show that the image quality is relatively good when the average intensity (gray) of the randomly modulated speckle is about 160. On the other hand, the contrast-to-noise ratio of the image gradually increases from 0.8795 to 1.241, 1.516, 1.755, 2.100 and 2.371 as the number of measurement frames increases from 2,000 to 4,000, 6,000, 8,000, 12,000 and 20,000, respectively. The experimental results are basically consistent with the theoretical analysis. The results are of great significance for the application of ghost imaging with incoherent light, such as sunlight, which is approximately regarded as blackbody radiation, in the field of remote imaging.
With the increasing demand for sustainable energy, advanced characterization methods are becoming more and more important in the field of energy materials research. With the help of X-ray imaging technology, we can obtain the morphology, structure and stress change information of energy materials in real time from two-dimensional and three-dimensional perspectives. In addition, with the help of high penetration X-ray and high brightness synchrotron radiation source, in-situ experiments are designed to obtain the qualitative and quantitative change information of samples during the charge and discharge process. In this paper, X-ray imaging technology based on synchrotron and its related applications are reviewed. The applications of several main X-ray imaging technologies in the field of energy materials, including X-ray projection imaging, transmission X-ray microscopy, scanning transmission X-ray microscopy, X-ray fluorescence microscopy and coherent diffraction imaging, are discussed. The application prospects and development directions of X-ray imaging in the future are prospected.
Introduction: Periodontal disease affects more than half of the population in Colombia and is estimated to be one of the leading causes of oral morbidity. Diagnostic aids that allow the evaluation of its extension and severity are of importance since this will provide reliable tools to quantify the severity of the problem. Objective: To determine the inter-examiner agreement for the detection of radiographic findings in patients with localized chronic periodontitis using conventional periapical radiography. Methods: Study of diagnostic tests including patients with localized chronic periodontitis, the tooth with the worst clinical insertion level and a single conventional radiograph per dental organ using parallelism technique. The radiographic evaluations were performed by two independent and blinded evaluators for the findings: lamina dura, bone defects and type of defect. The agreement obtained was estimated through Cohen’s Kappa. Results: A total of 125 radiographs were taken. The mean age was 38.8 ± 9.9, and 61.6% were women. Concordance for lamina dura was 0.08 (95% CI: -0.04–0.21), bone defects 1.00 (95% CI: 1.00–1.00); type of defect present 0.31 (95% CI: 0.29–0.38). Conclusions: Concordance was evaluated as null, almost perfect and acceptable for the findings lamina dura, presence of bone defects and type of defect respectively. For some findings and given the importance of the diagnostic and therapeutic processes, more accurate evaluations are needed which would result in a higher degree of agreement.
The integration of medical images is the process of registering and fusing them to obtain a greater amount of diagnostic information. In this work an analysis is performed for the integration of images obtained through computed axial tomography and magnetic resonance imaging, for which a tool was developed in the Matlab program, where the registration is implemented through equivalent features; in addition, the pairs of images are compared by several fusion rules, with a view to identify the best algorithm in which the resulting fused image contains the most information from the original representations.
In the present research work, we investigated the use of the image intensifier in the extraction of radiopaque foreign bodies in traumatology. First of all, it is necessary to clarify that this method constitutes an essential component of practically generalized use, in which low current level radiation is used, that is, fluoroscopic radiation, so that it can be applied for a considerably longer time than that of the longest radiographic exposure. This tool works with a tube intended for this purpose, which is known as fluoroscopy. The radiations from the tube pass through the patient and reach the serigraph, on which the image intensifier or fluoroscopic screen is mounted. In the latter case, this is where the chain ends, since it is on this screen that the image is formed and where the physician directly observes the region to be studied. It is also necessary to define that a foreign body is any element foreign to the body that enters it, either through the skin or through any natural orifice such as the eyes, nose, throat, preventing its normal functioning. It was possible to obtain as a result that the advantages of fluoroscopic navigation are the reduction of surgical time and the amount of irradiation, which goes from about 140 seconds without navigation to only 8 seconds, which is a substantial difference. Among the conclusions, it was possible to highlight that in the case of a radiopaque object, it is essential to have an image intensifier for localization of the foreign body during surgery; while in the case of a radiolucent foreign body, it is more advisable to locate it through the clinic, since these tend to form granulomas.
Currently there is a great acceptance in medicine and dentistry that clinical practice should be “evidence-based” as much as possible. That is why multiple works have been published aimed at decreasing radiation doses in the different types of imaging modalities used in dentistry, since the greater effect of radiation, especially in children, forces us to take necessary measures to rationalize its use, especially with Cone Beam computed tomography (CBCT), the method that provides the highest doses in dentistry. This review was written using such an approach with the purpose of rationalizing the radiation dose in our patients. In order to formulate recommendations that contribute to the optimization of the use of ionizing radiation in dentistry, the SEDENTEXCT project team compiled and analyzed relevant publications in the literature, guidelines that have demonstrated their efficiency in the past, thus helping to see with different perspectives the dose received by patients, and with this, it is recommended taking into account this document so as to prescribe more adequately the complementary examinations that we use on a daily basis.
Copyright © by EnPress Publisher. All rights reserved.