This study aims to explore the evolution of the human resources field in Western academia during the 1970s and 1980s, focusing on the trends in research topics across different decades. The analysis utilizes citation co-citation analysis, multivariate statistical analysis, and social network analysis. The research data were drawn from the Web of Science (WoS) database, comprising 1278 documents. By distinguishing between different time periods, the study identifies shifts in the field across two distinct time frames, visualized through multidimensional scaling maps. The results indicate that the 1970s were dominated by seven major research streams, while the 1980s introduced eight research streams, with “human resources” emerging for the first time as a prominent research frontier. The volume of literature, co-citation frequency, and citation counts all increased over time, reflecting the growing vibrancy and expanding scope of research in the field. Although citation co-citation analysis provides objective quantitative insights, issues such as the purpose of citations, the extent to which cited documents influence citing documents, and the varying layers of citation impact may introduce potential errors in the co-citation analysis results.
Due to the short cost-effective heat transportation distance, the existing geothermal heating technologies cannot be used to develop deep hydrothermal-type geothermal fields situated far away from urban areas. To solve the problem, a new multi-energy source coupling a low-temperature sustainable central heating system with a multifunctional relay energy station is put forward. As for the proposed central heating system, a compression heat pump integrated with a heat exchanger in the heating substation and a gas-fired water/lithium bromide single-effect absorption heat pump in the multifunctional relay energy station are used to lower the return temperature of the primary network step by step. The proposed central heating system is analyzed using thermodynamics and economics, and matching relationships between the design temperature of the return water and the main line length of the primary network are discussed. The studied results indicate that, as for the proposed central heating system, the cost-effective main line length of the primary network can approach 33.8 km, and the optimal design return temperature of the primary network is 23 ℃. Besides, the annual coefficient of performance and annual energy efficiency of the proposed central heating system are about 3.01 and 42.7%, respectively.
Copyright © by EnPress Publisher. All rights reserved.